STEP 11 START ICEMAKER

WARNING
Connect to potable water supply
only. A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).
WARNING
ELECTRIC SHOCK HAZARD
Attach tubing clamp using existing hole only. DO NOT
drill into the refrigerator.
AVERTISSEMENT
Raccordez l'appareil à une
alimentation d'eau potable seulement. Une alimentation
d'eau froide est requise pour faire fonctionner
la machine à glaçons et le pichet à remplissage
automatique. La pression d'eau doit se situer entre 40
et 120 psi. (275 à 827 kPa).
AVERTISSEMENT
Fixez le collier de serrage dans le trou présent seulement.
NE PERCEZ PAS dans le réfrigérateur.
ADVERTENCIA
Realice la conexión a un
suministro de agua potable únicamente. Se requiere
un suministro de agua fría para el funcionamiento de la
máquina de hielos automática y de la jarra de llenado
automático. La presión del agua deberá estar entre 40
y 120 p.s.i. (275 – 827 kPa).
ADVERTENCIA
Adhiera la abrazadera de la tubería usando el agujero
existente únicamente. NO perfore el refrigerador.
• The icemaker will begin operation automatically.
• Be sure nothing interferes with the sweep of the feeler
arm.
• Discard the first full bucket of ice cubes.
• To turn the icemaker off, slide the switch to O (OFF).
Power
Switch
RISQUE DE DÉCHARGE
ÉLECTRIQUE
PELIGRO DE DESCARGA
ELÉCTRICA
Icemaker
Feeler Arm

STEP 12 INSTALL TOEKICK

• Locate the supplied toekick (shipped taped to the
side of the refrigerator). Install the toekick assembly
with the 2 screws provided, adjust to the desired
height and tighten the screws.
IMPORTANT: A custom toekick can be installed to
match or complement the surrounding cabinetry but
can NOT cover the horizontal vent slots of the factory
toe kick.
36
31-1000452 Rev. 1