Magicfx SNOWCASE Series User And Installation Manual page 12

Table of Contents

Advertisement

Pause Timer
[sec] (0-600)
Output
Distance (0-
255)
Output Density
(0-255)
Extract Fluid
(On/Off)
Display Dimmer
(On/Off)
Factory
Defaults (Yes/
No)
Total Used [l]
Curr Use [l/
min]
Cycle Used [l]
Cycle Avg [l/
min]
Cycle Reset
(Yes/No)
Type (Alarm/
Error)
Serial Number
(DDDDD)
Unique ID
(HHHHHHHHHHHH)
Software
Version
Software CRC
Bootloader
CRC
Build Date
Up-Time
(DDDD:HH:MM:SS)
Effect-Time
(DDDD:HH:MM:SS)
12
MAGICFX
SNOWCASE — User and Installation Manual
®
This parameter represents the off time duration of the on/off cycle
of the effect.
Setting of the distance the snow is blown away. The 0-255 range is
comparable to the lighting console fader running from 0 upto
255.
Setting of the snow density. The 0-255 range is comparable to the
lighting console fader running from 0 upto 255.
This function empties the fluid hoses of the snowCase by running
the pump in reverse for a certain time.
Turn display dimmer on or off. If turned on, the display is dimmed
automatically 30 seconds after the last button push.
Restores the appliance factory default settings.
Indicates the total amount of snow fluid used since first use of the
machine.
Indicates the current snow fluid consumption.
Indicates the total amount of snow fluid used since the cycle was
reset.
Indicates the average snow fluid consumption since the cycle
was reset.
When set to Yes, this resets the cycle numbers above.
Toggle between the occured locking error (Alarm) list, and
blocking error (Error) list. Locking errors need intervention by user,
although they are "auto-reset" 3 times before the appliance
remains in error until reset by user. Blocking errors clear when the
triggering fault disappears. 16 locked, and 16 blocked errors are
logged. Top of the list shows the last occurring error.
Appliance serial number as also printed on the appliance label.
UID number as the appliance appears in the RDM device list after
running discovery.
Installed software version.
CRC of the functional software.
CRC of the bootloader software.
Release date of functional software.
Time counter which indicates how long the appliance has been
powered in total.
Time counter which indicates how long the effect has been activated
in total.