Download Print this page

Avaya 1101GT Installation Job Aid page 7

Open networking adapter
Hide thumbs Also See for 1101GT:

Advertisement

• Management IP Subnet Mask :
• Default Gateway IP Address :
• Primary DNS Server IP Address :
• Secondary DNS Server IP Address :
• DNS Domain Name :
• SDN Controller IP Address or Name :
• Syslog Server IP Address :
• Operational Mode : 0
• Password :
Note:
All the fields are empty except the Operational Mode, which is 0 for the SDN Controller Mode.
Use the following procedure if you want to reset the ONA to the factory default parameters:
Procedure
1. Wait until the ONA starts and the Status LED flashes green. (You can enter this mode
anytime after the ONA starts.)
2. On the Device side of the ONA, insert a paper clip into the reset switch and depress it for at
least five seconds. This action clears the parameters so they are all empty fields (except for
Operating Mode) and then resets the ONA.
ONA Operational Modes
The ONA has two operational modes:
• SDN Controller Mode (Mode 0, the default mode)
• Fabric Extend Mode (Mode 1)
During reboot, the system checks the Mode parameter and proceeds accordingly. The ONA stays in
the mode you select unless you depress the reset button for at least five seconds. This causes the
ONA to revert back to the factory default parameters.
To change operational modes, use the Manual Configuration menu as described in the next section
Modifying Manual Configuration parameters
You can also use the Manual Configuration menu to modify any of the other factory default
parameters. After you modify the parameters and save the configuration, the ONA stores your
changes in persistent memory and reboots.
Note:
Manual Configuration menu changes for default parameters are not required for SDN Controller
Mode 0 operation.