4. BMI Weighing

ON
1. Turn on the power by pressing the
ZERO
d
NET
kg
STABILIZED
lb
STEP ON
2. After all the segments flash, [0.0 kg] is displayed.
HEIGHT
cm
BMI
ft.in
LO
BMI MODE
BATTERY
d
NET
kg
STABILIZED
STEP ON
d
BMI MODE
BMI MODE
3. Please push
SET
d
kg
NET
STABILIZED
STEP ON
[0.0 kg] and the default height [170 cm] will be displayed.
cm
HEIGHT
BMI
LO
BMI MODE
BATTERY
d
HEIGHT
cm
BMI
4. Please set your height with the
LO
BMI MODE
BATTERY
(this can also be entered after you step on the scale).
d
NET
kg
STABILIZED
The person to be weighed should stand still in the middle of the scale.
STEP ON
The weight will be displayed.
HEIGHT
cm
BMI
LO
BMI MODE
BATTERY
d
BMI MODE
5. Once your height and weight have been established, please press
SET
Your weight and BMI figure will be displayed.
d
* Whenever you press the
kg
NET
STABILIZED
and height (can be changed with the
STEP ON
HEIGHT
* The display will return to [0.0 kg] and the default height [170 cm], if you press
BMI
ping off the scale.
LO
BMI MODE
BATTERY

5. Auto Power off Interval Setting

1. When the Scale power off,Press
2. The display turns to "Auto Power Off Interval Setting Mode" showing "20" as 20 minutes power off setting as default.
3. Press
(up arrow marking) or
BMI MODE
4. Press
key to complete.
SET

6. Changing Measurement Units

This function is used to change the measurement units on the display.
e.g. When changing the unit from kg to lb.
kg
NET
STABILIZED
STEP ON
d
kg/lb
1. Press the
kg/lb
d
NET
The measure shifts from kg to lb and the measurement units change.
STABILIZED
lb
STEP ON
6
ON
key.
ZERO
for at least two seconds.
SET
key.
BMI MODE
.
SET
BMI MODE
key in BMI mode, the scale will switch alternately between BMI
SET
key) display.
BMI MODE
ON
key and hold. Press
key. Release the holding
SET
ZERO
(down arrow marking) key and set 10 for 10 minutes and/or CONT for continuous setting if you need it.
key.
Specifications
Communication standard
EIA RS-232C
Communication method
Asynchronous method
Signal speed
2,400 baud
Data bit length
7 bit
Parity
EVEN
Stop bit
1 bit
An RS-232C connector (D sub 9 pin male) is attached to the side of the display box.
When connecting the display box with a personal computer, etc., please use an RS-232C cross cable.
Weighing Mode
When receiving 4 bytes of data as indicated in 1-1 while using the scale in weighing mode, weight data will be output in 14 bytes, as indicated in 1-2.
* While the scale is used with lb (pound) measurement units, the weight data will be output in lbs (pounds).
1-1 Reception data
1
2
3
4
D R
CR LF
1-2 Transmission data
1
2
3
4
5
S D
BMI Mode
While the scale is used in BMI mode, the output data will vary depending on the form of the received data.
When receiving 4 bytes of data, as indicated in 1-1, the scale will calculate your BMI using the currently input height figure, and 26 bytes
of data will be output, as indicated in 2-1 or 2-2, depending on the measurement unit.
When receiving 11 bytes of data, including measurement units and height figures, in the form indicated in 1-2 or 1-3, the scale will calcu-
late your BMI using these figures, and 26 bytes of data will be output, as indicated in 2-1 or 2-2, depending on the measurement unit.
BMI MODE
1-1 Reception data
after step-
SET
1
2
3
4
D R
CR LF
1-2 Reception data (height data when using kg)
BMI MODE
1
2
3
4
5
key.
SET
D H k g
*Please input 90-99cm height data as 090-099.
1-3 Reception data (height data when using lb)
1
2
3
4
5
D H L b 5 . 1 1 0
* Height data in ft. (feet) and in. (inches) will appear as follows.
5 feet, 11.0 inches will appear as 5.110.
* When INCH is 1 figure less than 10 inch, please put in 0 and input by 2 figures.
e.g. 2inch
02 inch
2-1 Transmission data (kg/cm)
1
2
3
4
5
S D
2-1 Transmission data (lb/ft. in)
1
2
3
4
5
S D
8.

RS-232C Communication Specifications

Names and connection methods for signal lines
Terminal no.
Signal name
1
2
RXD
3
TXD
4
5
GND
6
7
8
9
Details of Weighing Mode Transmission Data
Byte nos. 1-2
Byte nos. 3-4
Byte nos. 5-10
6
7
8
9
10 11 12 13 14
Byte nos. 11-12
Measurement units
7 5 . 0 k g
CR LF
Byte nos. 13-14
Details of BMI mode transmission data
Byte nos. 1-2
Byte nos. 3-4
Byte nos. 5-10
6
7
8
9
10 11
Byte nos. 11-12
Measurement units
1 8 0
CR LF
Byte nos. 13
Byte nos. 14-18
Byte nos. 19
Byte nos. 20-24
6
7
8
9
10 11
Byte nos. 25-26
CR LF
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
7 5 . 0 k g ,
1 8 0 ,
2 3 . 1
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
1 6 5 . 4 L b , 5 . 1 1 0 ,
2 3 . 1
1
5
6
9
SD: Unstable S_: Stable
Header
2 bytes fixed
SI: Overload, etc.
Separator
2 bytes fixed
2 spaces
Weight data
6 bytes fixed
Right-aligned
2 bytes fixed
Kg:kg Lb:lb
Terminator
2 bytes fixed
CR+LF
SD: Unstable S_: Stable
Header
2 bytes fixed
SI: Overload, etc.
Separator
2 bytes fixed
2 spaces
Weight data
6 bytes fixed
Right-aligned
2 bytes fixed
Kg:kg Lb:lb
Separator
1 byte fixed
1 comma
Height data
5 bytes fixed
Right-aligned
Separator
1 byte fixed
1 comma
BMI data
5 bytes fixed
Right-aligned
Terminator
2 bytes fixed
CR+LF
CR LF
CR LF
7