History Records; Maintenance; Arc Calibration; Clean Electrodes - Televes OSSGT Operating Instructions Manual

Electric-arc fusion splicer
Table of Contents

Advertisement

Parameter
Heating mode
Program selected to perform the heating
process.
Length of the heat-shrink protector for
Sleeve type
adjusting the heater of the device to that
measure.
Diameter of the heat-shrink protector for
Sleeve diameter
adjusting the heater of the device to that
measure.
Heating
Adjust the maximum heating temperature.
temperature
Confi gurable between 100ºC and 240ºC.
Time (in seconds) that the heating will be
working.
Despite its working range is adjustable
Heating
between 10 and 250 seconds, it is not
duration
recomendable to choose times higher of 100
seconds of continuated work (considerably
decreases the heater life cycle).

4.4 History records

In this section we can access and view all the logs that the
device has.
Parameter
Total Arc
Displays the total number of arcs that the
Number
device has launched.
Erases the count of the arcs performed by the
Clear Arc count
device.
Total records
Displays the total number of records that the
number
device has registered.
After pressing the "Menu" key a new section in
View records
which all the records registered by the device
are shown will be displayed.
Erases all the records that the device has
Delete records
registered.
Query fault
Displays the records of all the failed splices.
records
Delete fault
Erases all the records of the failed splices that
records
the device has registered.
Description
Description
Displays the images of the 20 last splices
that the device has performed, as long as the
Query image
saving picture option is activated ( see section
4.1)
Erases all the images present in the memory
Delete image
of the device.
4.5 Maintenace
In this section, adjustments regarding to the maintenance
of the device can be applied.
Parameters
An arc calibration launched by the device is

Arc Calibration

performed (see section 4.5.1).
A cleaning discharge is performed to erase

Clean electrodes

possible dirt present in the electrodes (see
section 4.5.2).
To substitute the electrodes due to possible
Replace
worn out of the same is mandatory to select
electrodes
this option and follow the steps indicated
(see section 4.5.3).
Self-diagnosis
A test is performed to verify the system status
Test
(see section 4.5.4).
Optical
An optical test is performed to verify the
correction
lenses status (see section 4.5.5)
Connection mode to a PC for the records
USB Mode
download and the software update(see
section 4.5.6)
4.5.1 Arc Calibration
Press the "Menu" key and follow the steps displayed on the
device:
Description
9