Download Print this page

Garnet SeeLevel II 900-D4S Single Manual page 13

Tank fluid monitor

Advertisement

value in barrels for 20mA output); the existing value will
disappear and the new value will be shown. The decimal
point location must match the decimal point for the
calibration, for example, if the calibration is entered with
2 numbers after the decimal point, then the 4-20 full scale
value must also have 2 numbers after the decimal point as
well. The display will show "dECI" after ENTER is pressed if
the decimals do not match, if this occurs simply re-enter the
correct value. If more than four digits are entered, the first
ones will scroll off the left side of the display. If a second
decimal point is entered, the first one will disappear. The
minimum value is 0.051/0.51/5.1/51 barrels, the status
display will show "toLo"(too Low) after ENTER is pressed
if a smaller number is attempted, if this occurs simply re-
enter the correct value. The decimal point is only valid as
X.XXX or XX.XX or XXX.X, a trailing decimal (XXXX.) will be
ignored.
9. To turn the 4-20 mA output off, enter a single "0" and press
ENTER.
10. Press ENTER to store the new 4-20mA value, the display
will show "CALC" while the gauge calculates the 4-20
calibration, then "Stor" will be shown momentarily.
ENTER is pressed without any number buttons being
pressed, a blank value will be stored and the 4-20 output
will not function properly.
11. EXIT MENU: To exit the programming mode, press ↑↑
FAST UP until the exit menu is accessed, the display will
show "LUC donE".
shown momentarily and the gauge will return to normal
operation.
12. If a menu is left without pressing ENTER, any change to that
menu item will NOT be stored. If no button is pressed for
3 minutes then the gauge will exit programming mode and
any changes which have not been stored will be ignored.
To access the Master Code menu (volume calibration, user
code, and copy mode):
1. Press and hold ENTER until "SECU COdE" appears (this will
take approximately 5 seconds).
2. Enter the 8 digit master security code (it will be shown as
you enter it) and press ENTER. If the code is incorrect, the
gauge will exit programming mode.
3. USER CODE MENU: If the code is correct then the user
900D4S Manual
Press ENTER, "Prog donE" will be
If
Page 13