Technical Data - Wallbe Driving eMobility Eco 2.0 Instruction Manual

Wallbox & charging column 3,7 kw to 22 kw
Table of Contents

Advertisement

Instruction Manual

11 TECHNICAL DATA

POWER CLASS 3,7 kW
Construction type
Number of charging
points
Charging capacity
Dimensions
wallbox
(H x W x D)
Weight
wallbox
Dimensions
charging column
(H x B x T)
Weight
charging column
Storage temperature
Operating temperature
(compliant with german
calibration law)
Operating temperature
(not compliant with ger-
man calibration law)
Relative humidity
Protection degree
Charging socket / char-
ging cable
Firmly attached charging
cable
Power contactor
Control fuse
Integrated
safety devices
RCD
(must be installed in the
sub-distribution)
Circuit breaker
Authorization
Housing lockable
Energy meter
Protocols
Interfaces
Protection class
Driving eMobility
Wallbox or charging column
1
16 A, 230 V, 1-phase
18 x 29 x 14 cm
approx. 2,5 kg
122 x 29 x 30 cm
approx. 11 kg
-30 to +70°C
-25 to +40°C
-25 to +55°C
30 to 95% (non-condensing)
IP54
Charging socket type 2
Additionally available:
Cable type 1 or type 2
Type 1 or type 2
No
1-pole, B6
RCM-module –
DC fault current detection. 6 mA
contactor monitoring
Lock release module
Type A
0,03 A / 25 A
Not integrated
Key switch
No
No
Modbus TCP/RTU
Ethernet RJ45, RS485
1
POWER CLASS 4,6 kW
Construction type
Wallbox or charging column
Number of charging
1
points
Charging capacity
20 A, 230 V, 1-phase
Dimensions
18 x 29 x 14 cm
wallbox
(H x W x D)
Weight
approx. 2,5 kg
wallbox
Dimensions
122 x 29 x 30 cm
charging colum
(H x B x T)
Weight
approx. 11 kg
charging column
Storage temperature
-30 to +70°C
Operating temperature
-25 to +40°C
(compliant with german
calibration law)
Operating temperature
-25 to +55°C
(not compliant with ger-
man calibration law)
Relative humidity
30 to 95% ( (non-condensing)
Protection degree
IP54
Charging socket / char-
Charging socket type 2
ging cable
Additionally available:
Cable type 1 or type 2
Firmly attached charging
Type 1 or type 2
cable
Power contactor
2-pole, 25 A
Control fuse
1-pole, B6
Integrated
RCM-module –
safety devices
DC fault current detection. 6 mA
contactor monitoring
Lock release module
RCD
Type A
(must be installed in the
0,03 A / 25 A
sub-distribution)
Circuit breaker
Not integrated
Authorization
Key switch
Housing lockable
No
Energy meter
No
Protocols
Modbus TCP/RTU
Interfaces
Ethernet RJ45, RS485
Protection class
1
9/13