10 DISPOSAL

Please note that this product must not be disposed
of with household waste. The product must be dispo-
sed of at a designated collection and return point for
the disposal and recycling of electrical and electronic
equipment. Observe all applicable national and local
legislation. Further information can be obtained from
your local authorities.
For safety reasons, the charging station may only be
dismantled by a qualified electrician or a wallbe® spe-
cialist partner. Ask your contact person whether he will
take charge of the disposal for you.
Driving eMobility

11 TECHNICAL DATA

POWER CLASS 22 kW
Construction type
Charging column
Number of charging
2
points
Charging capacity
32 A, 400 V, 3-phase
Dimensions
270 x 536 x 330 cm
charging column
(H x W x D)
Weight (charging column
approx. 2 t
with roof)
Storage temperature
-30 to +70°C
Operating temperature
-25 to +55°C
Relative humidity
30 to 95% (non-condensing)
Protection degree
IP54
Charging socket
2x charging socket type 2
(Additionally available:
socket)
Power contactor
4-pole, 40 A
Control fuse
1-pole, B6
Integrated
RCM-module –
safety devices
DC fault current detection. 6 mA
contactor monitoring
Lock release module
RCD
Type A
(must be installed in the
0,03 A / 40 A
sub-distribution)
Circuit breaker
Not integrated
Authorization
RFID,
App
Housing lockable
Optional
Energy meter
Yes
Protocols
Modbus TCP/RTU, OCPP 1.6J
Interfaces
Ethernet RJ45, RS485, GSM/UMTS
Protection class
1
shockproof