Transport And Storage; Welding Torch Cooling System; Permitted Torch Coolant - EWM Drive XQ Operating Instructions Manual

Wire feed unit
Table of Contents

Advertisement

5.1.1.2

Transport and storage

Storage in a closed room, temperature range of the ambient air:
-30 °C to +70 °C (-22 °F to 158 °F)
Relative humidity
up to 90 % at 20 °C (68 °F)
[1]
Ambient temperature dependent on coolant! Observe the coolant temperature range of the torch coo-
ling
5.1.2

Welding torch cooling system

Insufficient frost protection in the welding torch coolant!
Depending on the ambient conditions, different liquids are used for cooling the welding
torch > see 5.1.2.1 chapter.
Coolants with frost protection (KF 37E or KF 23E) must be checked regularly to ensure that the
frost protection is adequate to prevent damage to the machine or the accessory components.
The coolant must be checked for adequate frost protection with the TYP 1 frost protection
tester .
Replace coolant as necessary if frost protection is inadequate!
Coolant mixtures!
Mixtures with other liquids or the use of unsuitable coolants result in material damage and ren-
ders the manufacturer's warranty void!
Only use the coolant described in this manual (overview of coolants).
Do not mix different coolants.
When changing the coolant, the entire volume of liquid must be changed.
Dispose of the coolant in accordance with local regulations and the material safety data sheets.
5.1.2.1

Permitted torch coolant

Coolant
KF 23E (Standard)
KF 37E
099-005570-EW501
29.08.2019
[1]
Temperature range
-10 °C to +40 °C (14 °F to +104 °F)
-20 °C to +30 °C (-4 °F to +86 °F)
Design and function
Transport and installation
15