Rectifying faults
Error messages (power source)
Category
a)
b)
58
59
60
61
62
[1]
factory setting
[2]
option
[3]
only machine series Titan
[4]
not machine series Titan
40
Error
Possible cause
c)
Short circuit
Check welding circuit for short
circuit
Incompatible
A machine connected to the
machine
system is not compatible
Incompatible
A machine's software is not
software
compatible.
Welding moni-
The actual value of a welding
tor
parameter is outside the spe-
cified tolerance field
System com-
System component not found
[3]
ponent
Remedy
Check welding circuit; isolate
welding torch before deposi-
ting
Please disconnect the incom-
patible machine from the sys-
tem
Inform Service
Observe tolerance fields; ad-
just welding parameters
Inform Service