Error
Possible cause
c)
Sec. overvolta-
Overvoltage at output: Inverter
ge
error
Earth fault (PE
Connection between welding
error)
wire and machine casing
Quick shut-
Removing the logical signal
down
"robot ready" during the pro-
cess
Coolant excess
Coolant is overheating (>=70°C
[3]
temperature
/ >=158°F)
coolant return line
Fan blocked, dirty or defective
Air inlet or outlet blocked
[3]
Error I>0
[3]
Error UIST
Short circuit in welding circuit
before welding
[3]
Error IIST
Short circuit in welding circuit
before welding
Ignition error
No ignition occurred during a
process start with automated
machines
Arc interruption An arc interruption occurred
during welding with an automa-
ted system
Emergency
The emergency stop circuit of
stop
the power source has been
activated.
No wire feeder
After switching on the automa-
ted system, no wire feeder was
detected
No wire feeder
Wire feeder 2 not detected
2
[2]
VRD error
Open circuit voltage reduction
error
WF excess
Overcurrent detection on wire
current
feeder
Mains phase
One phase of the mains voltage
failure
has failed
Slave tacho
Wire feeder fault (slave drive)
error
Permanent overload of the wire
drive (slave drive)
Error messages (power source)
Remedy
Inform Service
Remove electrical connection
Eliminate errors on the higher-
level control
Allow the power source to
[1]
measured in the
cool down (mains switch to
"1")
Check fan, clean or replace
Check air inlet and outlet
Inform Service
Eliminate short circuit in
welding circuit; remove exter-
nal sensor voltage
Eliminate short circuit in
welding circuit
Check the wire feeding, check
the connections of the load
cables in the welding circuit,
clean corroded surfaces on
the workpiece before welding
if applicable
Check wire feeding; adjust
welding speed.
Disable the activation of the
emergency stop circuit (relea-
se protective circuit)
Check or connect control
cables of wire feeders; check
the identification number of
the automated wire feeder (for
1DV: number 1, for 2DV: each
a wire feeder with number 1
and a wire feeder with number
2)
Check or connect the control
lines of the wire feeders
if necessary, disconnect ex-
ternal machine from the
welding circuit; inform Service
Do not place the liner in tight
radii; check wire core for
smooth movement
Check mains connection,
mains plug and mains fuses
Check connectors, cables,
connections
Do not place the liner in tight
radii; check wire core for
smooth movement
Rectifying faults