Measurement Setup Parameters
Trigger delays:
*On "Segmented Capture" feature the free run triggered is not supported.
(Segmented Capture feature may be accessed via the MeasSetup > Time
menu)
**M9703A-DDC option is required for Magnitude triggering.
Trigger Holdoff: The trigger holdoff is not supported by the M9703A digit-
izer.
Soft Front Panel Control: The 'Disconnect' feature can be used to pause the VSA and
release its control of the M9703A digitizer. Then the digitizer can be used inde-
pendently from the VSA, for example, using the MD1 SFP application. Independent
control must be released before resuming VSA measurements. When returning to the
VSA and starting or resuming a measurement, the VSA will restore the digitizer state
that was set before disconnected.
Hardware: Set up an Analyzer Configuration with the M9703A digitizer as the Logical
Instrument, as described in Measurement Configuration Setup.
Overlap: The M9703A digitizer does not support overlap processing. However, over-
lap processing is available during recording playback.
Preset: The default parameter settings that are different from the 'Preset Setup' set-
tings are listed below. (Any parameters not listed here are set to the same value as
Preset Setup.)
Recording: the VSA application enables time data recording from the M9703A digitizer
to the PC's disk drive. The length of time waveform recording is limited by the memory
available on the M9703A digitizer.
Setup Save/Recall: The M9703A digitizer state is not saved when the VSA application
is closed. When a setup is recalled into the VSA, the M9703A digitizer state is set
appropriately based on the recalled VSA setup.
13
Trigger
Max Pre-Trigger Delay
Type
External
VSA increases the record size to make the
pre-trigger delay fit (limited by the amount
acquisition memory available).
Magnitude**
–137 samples * sampling Interval
Max Post-
Trigger
Delay
1 second
1 second
M9703A Hardware Extension of 89600 VSA Software