Haier Super Match Series Service Manual page 68

Table of Contents

Advertisement

Item
Function
Rating capacity
Heating pdesign(-10℃ )
Rated power input (indoor + outdoor)
Rated current input (indoor + outdoor)
EER / COP
SEER / SCOP
Minimum capacity
Minimum power input
Maximum capacity
Maximum power input (indoor + outdoor)
Power source
Max. running current (indoor + outdoor)
Power facor(under rating power input)
Fuse size (recommended size)
Compressor
Fan
Outdoor unit
Heat exchanger
Dimension
(WxDxH)
Refrigerant control method
Defrosting method
Crankcase heater power
Noise level
Weight
Refrigerant
Pipe
Connecting method
Piping
Between I.D &O.D
Model
Model / Manufacture
Oil charge and type
Type
Number
Type × Number
Speed
Motor output/input power
Air-flows (H/M/L)
Type / Diameter
row
Face area
External
Package
Sound power level
Sound pressure level
Net / Shipping
Type / Charge
No need to recharge
Recharge
Liquid
Gas
Drop between IU & OU
Piping length between IU & OU
Total liquid piping length
Drop between indoor units
Max. drop between IU &OU
Max. drop between IU &OU
Max. drop between indoor units
Max. piping length between IU & OU
Max. total length
Super Match
——
Cooling
W
9100
W
W
2600
A
11�3
W/W
W/W
W
1500
W
W
11000
W
4000
——
A / A
17�4
——
99%
A
——
——
——
——
——
r/min
W
m³/h
mm
——
mm
mm
——
——
W
dB(A)
dB(A)
kg / kg
kg
m
g/m
mm
mm
——
m
m
m
m
m
15(indoor unit lower than outdoor unit)
m
15 (indoor unit higher than outdoor unit)
m
m
m
67
5U34HS2ERA
Heating
10200
8100
2830
12�3
3�5
3�6
3�4
3�5
1800
550
550
11500
4000
1PH, 220-230V~, 50/60Hz
17�4
99%
25
TNB220FLHMC-L / MELCOM
870CC/ FV50S
Twin Rotary (DC inverter)
1
Axial × 1
High 900
100/125
about 4000
TP2M / 7.0
2
about 0.75
948/340/840
1040/430/1000
PMVs
Automatic by reversible cycle
none
67
58
77/88
R410A / 3�4
40
20
5* Φ6.35
4* Φ9.52+1*Φ12.7
Flared
≤7.5
≤10
≤40
≤1
5
25
80