Haier Super Match Series Service Manual page 161

Table of Contents

Advertisement

Super Match
Operation
1. Proceed through main interface→Menu→Other→enter the high-class user password→Temp.
Compensation→press "Enter" to initiate.
2. When in this interface, use the upward and downward keys to set the temperature value; the range of
O
O
Celsius degrees is -4
C to 4
C; the default value is 0; the range of Fahrenheit degrees is -7 to +7.Pressing
"Enter" value change is done;If pressing "Return" original value is retained.
• Additional functions
1.Special set is only effective to some types, with order ineffective if no such function equipped in the
corresponding indoor units.
2.When powered on, the default static pressure grade is 1 and no rated value displayed; when communication
stabilized (about 3 minutes later), static pressure and rated state can be checked.
3.Press up/down key to switch among Static pressure, rated value, wired controller group No.; press left/right
key to move the cursor in every line and then press OK key to confirm the setting.