Operation
Sleep Operation
Press
button to enter additional options, when
cycle display to
,
enter to sleep function.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
higher than temp.setting.After another 1 hours,temp.rises
O
futher.The unit will run for further 6 hours then stops
by 1
C
Temp. is higher than temp.setting so that room temperature
won't be too low for your sleep.
SLEEP operation starts
1 hr
Rises 1
1 hr
Temp.setting
In COOL, DRY mode
In HEAT mode
2.
1 hours after SLEEP mode starts,temp will become 2
lower than temp.setting.After another 1 hours,temp
O
decrease by 2
C futher.After more another 3 hours,temp.
O
C
rises by 1
futher.The unit will run for further 3 hours then
stops.Temp.is lower than temp. setting so that room
temperature won't be too high for your sleep.
Temp.setting
1 hr
Decreases 2
1 hr
Decreases 2
3 hrs
SLEEP
operation starts
In HEAT mode
In AUTO mode
3.
The unit operaters in corresponding sleep mode
adapted to the automatically selected operation mode.
will flash. And then press
SLEEP operation stops
Approx.6hrs
O
Rises 1
C
O
C
Unit stop
Unit stop
O
C
O
C
3 hrs
Rises 1
O
C
SLEEP
operation stops
4. In FAN mode
It has no SLEEP function.
5.Set the wind speed change when sleeping
If the wind speed is high or middle before setting for the
sleep, set for lowing the wind speed after sleeping.
If it is low wind, no change.
Note
When TIMER function is set, the sleeping function can't be
set up .After the sleeping function is set up
TIMER function, the sleeping function will be cancelled; the
machine will be in the state of timing-on.
TURBO/QUIET Operation
(1)
TURBO
Operation
When you need rapid heating or cooling, you can use this function.
O
1
C
Press
button to enter additional options, when cycle
display to
,
turbo function. When cancel the function, please enter
additional options again and to cancel turbo function.
(2)
QUIET Operation
Press QUIET button, the remote controller will show
and then achieve to the quiet function. Press again this
QUIET button , the quiet function will be cancelled.
Note
During TURBO operation, in rapid COOL mode , the room
O
C
will show inhomogeneous temperature distribution.
Long period QUIET operation will cause effect of not too
cool or not too warm.
304