Download Print this page

Setting Definitions - Yale Assure Lock YRD216 Installation And Programming Instructions

Keypad deadbolt
Hide thumbs Also See for Assure Lock YRD216:

Advertisement

Setting Definitions
Settings
Master Entry Code
All Code Lockout Mode
Audio Mode
Auto Re-lock
Inside Indicator Light
One Touch Locking
Privacy Button
Wrong Code Entry Limit
Shutdown Time
*The Master Entry Code must be created prior to any other programming of the lock.
Default Setting
The Master Entry Code is used for programming
and for feature settings. It must be created prior to
Creation
required*
programming the lock. The Master code will also
operate (unlock/lock) the lock.
This feature is enabled by the Master Entry Code.
When enabled, it restricts all user (except Master)
Entry Code access. When attempting to enter a
Disabled
code while the lock is in All Code Lockout mode,
the keypad flashes 8 times and the lock beeps 3
times as well.
The audio setting for entry code verification is set
Enabled
to enabled (1) by default; otherwise it can be set to
disabled (3) for quiet areas.
After a successful code entry or manual unlock
with the key, the lock will automatically re-lock after
each unlock in an effort to keep your home secure.
Disabled
This feature is optional, and can be turned off.
In the ON mode, the lock will automatically re-lock
after thirty (30) seconds.
Located on the inside lock. Shows active status
(Locked) of lock and can be enabled or disabled in
Disabled (Off)
the Advanced Lock Settings (Main Menu selection
#3).
When the latch is retracted, activating the keypad
will extend the latch (during Auto Re-lock duration
Enabled
or when Auto Re-lock is disabled).
When One-Touch Re-lock is not in use (disabled),
any valid PIN code will re-lock the lock.
Privacy mode is disabled by default. Enable Privacy
mode by pressing the privacy button for 4 seconds
Disabled
to put the lock in do-not-disturb mode (all pin
codes are disabled).
After five (5) unsuccessful attempts at entering a
valid entry code, the lock will shut down and not
5 Times
allow operation for sixty (60) seconds.
The Lock will shutdown (flashing keypad) for sixty
(60) seconds and not allow operation after the
60 Seconds
wrong code entry limit (5 attempts) has been met.
18
P/N YRD216-MNL-0002 Rev G
Definition