SREPN Maintenance
Maintenance procedure
3. If necessary, refer to FIBER-LK Maintenance object in Chapter 9 of
DEFINITY ECS Release 9 Maintenance for R9r for more information.

Reconnect the Release 9r to the EPN

!
CAUTION:
Ensure that the links are repaired before proceeding with the next section.
See
To reconnect the SREPN to the Release 9r:
1. Set the switch on the TN2301 circuit pack to the RSTR position for at least
1 second and return the switch to the AUTO position.
OR
From a remote dial-in connection to the SRP, use the restore survivable-
remote-link command to reset the SRP. See the
location''
2. Check for the following LED status:
3. Wait at least 3 minutes while the EPN goes through its cold restart.
4. Check the status of the link connections (status health) on both the
Release 9r and the SRP systems to determine whether the link between
the Release 9r and the EPN is up
c. Use the release fiber-link number [ a-pnc | b-pnc ] if duplicated,
command to restore the fiber connections.
d. Test the fiber connection again with the test fiber-link number [ a-
pnc | b-pnc ] if duplicated, [ short | long ] command.
e. If all tests on all components PASS, skip to the
status''
section.
''Fault isolation procedures''
section later in this chapter.
Red (SURVIVE MODE ON) is off
Green (AUTO) is on steady, meaning that the SREPN is ready to
assume processor control for the EPN should another link failure
occur.
for troubleshooting help.