UL/CSA Application Notes

The PS3701A-T41-DU-E66 unit is a UL/CSA listed product (UL File No. E220851). Please pay special
attention to the following instructions when applying for UL/CSA approval for machinery which includes
any of these PS-A unit.
The PS-A conforms as a component to the following standards:
UL508 Industrial Control Equipment
CAN Std C22.2 No. 14-1995 CAN/CSA 22.2 No.60950
PS3701A-T41-DU-E66 (UL Registration Model No.:3280022-01)
• Equipment with a PS-A unit mounted in it requires UL/CSA evaluation for the combination of the PS-A
unit and equipment.
• The PS-A unit must be used as a built-in component of an end-use product.
• Use the PS-A indoors only.
• When connecting the PS-A unit's power cable, be sure to use a cable that is
appropriate for the current and voltage used and that has conductive wires that are AWG18 or
larger.
• When using the PS-A unit in an end-use product, be sure to install the PS-A unit's power cut-off
switch where the operator can easily reach it.
• Danger of explosion if backup battery is incorrectly replaced. Should be replaced only with same
or equivalent type recommended by the manufacturer. Dispose of used batteries according to the
manufacturer's instructions.
• Be sure the unit the PS-A unit is built into uses a UL508 compatible structure.
The PS3701A-T41-DU-E66 unit is CE marked, EMC compliant product.
<Complies with the following Standards>
• Safety
EN60950
• EMI
EN61000-6-4, EN55011 (Group 1, Class A)
• EMS <EN61000-6-2/EN61131-2>
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-12
• FCC
47CFR Part 15 Class A
If the following requirements are not met, the PS-A may fail to meet EN60950 standard requirements.
• The PS-A must be used as a built-in component of an end-use product.
• Use the PS-A indoors only.
• When connecting the PS-A unit's power cable, be sure to use a cable that is appropriate for the current
and voltage used and that has conductive wires that are AWG18 or larger.
• When using the PS-A unit in an end-use product, be sure to install the PS-A unit's power cut-off switch
where the operator can easily reach it.
• There is a danger of explosion if the backup battery is incorrectly replaced. This battery should be re-
placed only with same or equivalent type recommended by the manufacturer. Dispose of used batteries
according to the manufacturer's instructions.
• Be sure the PS-A unit's enclosure is an EN60950 approved sheet steel structure.
E-2