Install the required spiral on the holder (fig. 36) and turn it until the spiral end clicking position.
After the spiral replacement put the shelf in place and connect the motors.
Replacing single cells with double cells
1. Remove the four shelf barriers in the direction shown by arrows in fig. 37.
2. Disconnect the motor connectors (fig. 38) and remove all motors with spirals.
3. Remove any four spirals from the holders (see above).
4. Install the spirals on the motor holders (see above), moreover, use two spirals with different spool-
ing directions but with an identical spooling pitch.
5. Install the motors on the shelf and restore the connections.
4
3
1
figure 37 - Shelf with single cells
After changing the shelf configuration test the motor operation. For this enter the service menu and
choose the (Snack - Service) menu item. Then touch the Test Motor button (select the cell number) - see
section 9.
Note: When using high products the use of high barriers is recommended.