SETTING
Min outdoor control temperature, °С
Max outdoor control temperature, °С
Temperature sensors type
Min top temperature, °С
Max top temperature, °С
Version 1.3 / December 2018
DESCRIPTIoN
Setting the minimum operating temperature for street per-
formance automata.
SET MIN – specifies the temperature, at which the control
compartment heating is activated.
Setting the maximum operating temperature for street per-
formance automata.
SET MAX – specifies the temperature, at which the control
compartment heating is deactivated.
This setting specifies which sensors are installed in the
vending machine.
KTY81/110 - when all (four) sensors are KTY81/110 type;
bottom EKS-211 - when a sensor at the bottom of the
chamber and the evaporator sensor are EKS-211, and all
other sensors are KTY81/110;
all EKS-211 - when all thermal sensors are EKS-211 type.
The setting operates on vending machines with the tem-
perature control at the top of the cabinet only (with an ad-
ditional fan and shutter).
It specifies the temperature range, which should be at the
top of the cabinet.
If min.=max., then the temperature control at the top is de-
activated.
VALUE
Input value
Input value
KTY81/110
bottom EKS-211
all EKS-211
Input value