Verifying successful NIC replacement from the ACM

acme-dp4400-ACM:~ # showfru network
Collecting Data............
______________________________________________________________________________
| Name
|=============================================================================|
| NIC Integrated 1| 1
| NIC Integrated 1| 2
| NIC Integrated 1| 3
| NIC Integrated 1| 4
| NIC Slot 1
| NIC Slot 1
| NIC Slot 1
| NIC Slot 1
| NIC Slot 2
| NIC Slot 2

Start up the IDPA

Start up the IDPA from Dell server

Start up the IDPA from iDRAC

After the NIC is replaced and power has been re-applied, you can run the FRU
command line verification from the ACM to ensure that the replacement was
successful.
Procedure
1. From the ACM, type the following command: # showfru network
The screen displays that the system is collecting data. When the data collection
is completed, the screen displays status information for ports the NIC.
| Port| Link Status| Model Name
| Up
| Ethernet 10G 4P X710 SFP+ rNDC
| Up
| Ethernet 10G X710 rNDC
| Down
| Ethernet 10G X710 rNDC
| Down
| Ethernet 10G X710 rNDC
| 1
| Down
| Ethernet Converged Network Adapter X710|
| 2
| Down
| Ethernet Converged Network Adapter X710|
| 3
| Down
| Ethernet Converged Network Adapter X710|
| 4
| Down
| Ethernet Converged Network Adapter X710|
| 1
| Up
| Gigabit 2P I350-t Adapter
| 2
| Down
| Gigabit 2P I350-t Adapter
2. Verify that the status information for the NIC matches the information shown in
the example output.
You can start the IDPA from the Dell server through iDRAC.
Switch on the power button on the Dell server.
Procedure
1. Turn on the iDRAC and log in to iDRAC from its UI using
password.
2. Click the Power On System button.
Note
The ACM will be accessible within approximately 20 minutes.
3. Connect to the ACM by accessing the https://<ACM_IP>:8543 URL from the
browser.