Remove and replace assemblies
Connect the I/O cables and power cords
Verifying successful DIMM replacement from the ACM
acme-dp4400-ACM:~ # showfru dimm
Collecting Data............
________________________________________________________________
| ID| Status| Manufacturer| Part#
|===============================================================|
| A1| OK
| Samsung
| A2| OK
| Samsung
| A3| OK
| Samsung
| A4| OK
| Samsung
| B1| OK
| Samsung
| B2| OK
| Samsung
| B3| OK
| Samsung
| B4| OK
| Samsung
Dell EMC Integrated Data Protection Appliance DP4400 2.4 Service Procedures Guide
44
Figure 32 Slide the system into the cabinet
This procedure is used to connect the peripherals and power to the system.
Procedure
1. Using the connection information recorded on the labels, connect the I/O
cables to the system.
2. Plug the power cords into the power supplies.
After a DIMM is replaced and power has been re-applied, you can run the FRU
command line verification from the ACM to ensure that the replacement was
successful.
Procedure
1. From the ACM, type the following command: # showfru dimm
The screen displays that the system is collecting data. When the data collection
is completed, the screen displays status information for the DIMMs.
| M393A4K40BB2-CTD| 364BB912| 32768 MB|
| M393A4K40BB2-CTD| 364B9A1B| 32768 MB| *
| M393A4K40BB2-CTD| 364BA009| 32768 MB|
| M393A4K40BB2-CTD| 36324964| 32768 MB|
| M393A4K40BB2-CTD| 36324B7D| 32768 MB|
| M393A4K40BB2-CTD| 3632553D| 32768 MB|
| M393A4K40BB2-CTD| 36325451| 32768 MB|
| M393A4K40BB2-CTD| 36324988| 32768 MB|
| Serial# | Size
|
Need help?