Explanation Of Parameters - Project EV ATESS EVA-11S Quick Installation Manual

3-phase ac charger
Table of Contents

Advertisement

Overview of Parameter setting page
enlarged view of parameter setting page_1
enlarged view of parameter setting page_2

Explanation of parameters:

(1)Firmware version of the Charger. This item cannot be modified here on the
setting page.
Fig.1
(2)Charger ID, this is the unique identification of the Charger. If the charger is to
be connected to Growatt back-office server, this ID must be set as the serial number
on the nameplate of the Charger. Otherwise the Charger cannot be registered on the
server.
Fig.2
(3)Charger IP. The default IP is 192.168.1.5. It is not suggested to change the
default IP. If you have changed the default IP and forgot the new IP, you can reset the
charger to factory setting by long press the reset button(the reset button on control
board, not the red emergency stop button) until the charger reboot. Then you can
use the default 192.168.1.5 for access.
Please note: After restoring the charger to factory setting, you'll need to reset
the charger ID(same as serial number, can be found on the nameplate sticker)
and server url, otherwise the charger won't be connected to the back-office
server.
Fig.3