Installer Manual Magnum 742-762 - Maintenance
9.6.7. Motor replacement
No.
A
Remove the controller cover (1). See 9.6.5. Controller cover disassembly, page 77.
B
Press the controller locking pad (4) and slide the controller (2) out of its position.
C
Loosen the two screws (6).
D
Remove the motor (5).
E
Disconnect the motor cable (3) from the controller (2).
Note
To replace the motor, you also have to disassemble the optical sensor. See 9.6.9. Optical
sensor and controller replacement, page 80.
F
Reverse above procedure steps to rebuild.