Motor Replacement - Pentair AUTOTROL MAGNUM 742 Installer Manual

Table of Contents

Advertisement

Installer Manual Magnum 742-762 - Maintenance

9.6.7. Motor replacement

No.
A
Remove the controller cover (1). See 9.6.5. Controller cover disassembly, page 77.
B
Press the controller locking pad (4) and slide the controller (2) out of its position.
C
Loosen the two screws (6).
D
Remove the motor (5).
E
Disconnect the motor cable (3) from the controller (2).
Note
To replace the motor, you also have to disassemble the optical sensor. See 9.6.9. Optical
sensor and controller replacement, page 80.
F
Reverse above procedure steps to rebuild.