Installer Manual Magnum 742-762 - Programming
6.3.3.8 Amount of brine used per regeneration
Set desired brine amount in g/L.
A
Press
.
→ Setting flashes.
B
Adjust displayed settings with
C
Press
to validate the selection and advance to the next
parameter using
6.3.3.9 Estimated system capacity
Note
The system capacity is displayed in kilograms equivalent CaCO
before a regeneration is necessary.
Note
The system capacity is calculated by the Logix software, using the resin volume, brine
dosage and hardness settings.
Note
This parameter can be override for 762 controller and is view only for 742 controller.
Set the estimated system capacity on the controller.
A
Press
.
→ The amount number flashes.
B
Adjust displayed capacity with
C
Press
to validate the selection and advance to the next
parameter using
6.3.3.10 Hardness (762 controller only)
Set inlet water hardness at installation site.
A
Press
.
→ The hardness number flashes.
B
Adjust displayed hardness number with
C
Press
to validate the selection.
→ Initial programming is now complete. The controller will
return you to the normal operation mode.
52 / 106
and
.
or
.
and
.
or
.
and
.
Ref. MKT-IM-012 / C - 25.10.2019
of hardness removed
3