Christie FHD553-X Technical Reference

Serial commands
Hide thumbs Also See for FHD553-X:

Advertisement

Quick Links

Technical Reference
020-001659-01
FHD553-X
Serial Commands

Advertisement

Table of Contents
loading

Summary of Contents for Christie FHD553-X

  • Page 1 Technical Reference 020-001659-01 FHD553-X Serial Commands...
  • Page 2 The warranty does not apply to any product where the serial number has been removed or obliterated. The warranty also does not apply to any product sold by a reseller to an end user outside of the country where the reseller is located unless (i) Christie has an office in the country where the end user is located or (ii) the required international warranty fee has been paid.
  • Page 3: Table Of Contents

    IR control code list..........23 FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 4: About External Controls

    IP address of the display panel and send commands using the Telnet protocol. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 5: Examples: Serial Commands And Responses

    07 01 01 47 56 45 08 07 01 00 47 56 45 S(0)...S(5) 08 display panel. (S(0)...S(5) = firmware version in ASCII) FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 6: Product Documentation

    About external controls Product documentation For installation, setup, and user information, see the product documentation available on the Christie website. Read all instructions before using or servicing this product. 1. Access the documentation from the Christie website: • Go to this URL: http://bit.ly/2CqwJJO or https://www.christiedigital.com/en-us/digital-signage/products/lcd-flat-panels/ultra-series...
  • Page 7: Serial Command List

    = High byte of By*10000, bD18 = Low byte of By*10000. • bD19 = High byte of WY*16, bD20 = Low byte of WY*16. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 8 55 53 42 value (128~383) 0~100 Current Red Offset 55 4F 52 value (-50~50) 0~100 Current Green Offset 55 4F 47 value (-50~50) FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 9: Other Controls

    PIP small PIP medium PIP large PIP side-by-side PIP source 50 49 4E selection Digital DVI HDMI 1 HDMI 2 DisplayPort FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 10 RIGHT key ENTER key EXIT key VGA key DVI key HDMI 1 key HDMI 2 key DISPLAYPORT key SOURCE key P-SOURCE key FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 11 Wake up VGA only 57 46 53 from sleep VGA, Digital, selection RS232 Never sleep Scheme User 53 43 4D selection FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 12 4F 54 54 diagnosis operation time (minutes) 4 Bytes Operation time 4F 54 53 (minutes) 4 Bytes Error code 45 52 52 FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 13 The 10th error log 4C 4D 41 *If a value of 0 is entered, the command is broadcast to all panels in the array. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 14: Using The Video Wall Toolbox Application

    3. Verify that the baud rate for the RS232 connection on the control computer matches the baud rate of the display panel. The default baud rate is 115200. 4. Launch The Video Wall Toolbox application. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 15 5. To specify the size of the video wall, in the Video Wall Size fields, enter the number of columns and rows in your video wall. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 16: Understanding Functions Of The Video Wall Toolbox Application

    Adjustment screen, and the Remote Control screen. • The Video Wall Adjustment screen provides the same controls as the Multi-Display Control menu on a display panel. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 17 Using the Video Wall Toolbox application • The Color Adjustment screen provides the same image quality controls as the Image Settings menu on a display panel. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 18 Using the Video Wall Toolbox application • The Remote Control screen provides the same functionality as the hand-held remote control. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 19: Entering Rs232 Commands In Ascii Format

    Learn how to send and receive RS232 commands using the Video Wall Toolbox application. Use the RS232 Command screen to manually enter supported RS232 commands in ASCII format. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 20 6. Click Send. If the command is successfully executed, the command and the response from the target display panel appear in the window. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 21: Entering Rs232 Commands In Hexadecimal Format

    8. Click Send. If the command is successfully executed, the command and the response from the target display panel appear in the window. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 22: Generating A Test Pattern

    • To generate an external test pattern from the control computer, under Test Pattern from Computer, select a test pattern. FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 23: Using Discrete Ir Codes

    IR control code list Learn the IR control codes. Customer code Data code Function 40AF 04FB INFO 40AF 1CE3 POWER 40AF 07F8 FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 24 40AF 12ED ENTER 40AF 05FA EXIT 40AF 14EB SCALING 40AF 17E8 BRIGHT 40AF 18E7 CONTRAST 40AF 1EE1 AUTO 40AF 0FF0 SOURCE FHD553-X Technical Reference–Serial Commands 020-001659-01 Rev. 1 (01-2019) Copyright 2019 Christie Digital Systems USA, Inc. All rights reserved. ©...
  • Page 25 Corporate offi ces Worldwide offi ces Christie Digital Systems USA, Inc. Australia Germany Republic of South Africa United Kingdom Cypress ph: +61 (0) 7 3624 4888 ph: +49 2161 664540 ph: +27 (0)11 510 0094 ph: +44 (0) 118 977 8000...

Table of Contents