The software shall track the state of each thermocouple and the state of the thermocouple reading compared
to the set point. If the software finds an error, it will begin to time it. When the timer reaches 15 minutes, an
error code(s) will display (flash) on the screen. This shall continue indefinitely until the zone is +/- 5 degrees of
the set point or the unit is power cycled off and the 15 minute time starts again. If an error is still present, it
will be displayed until corrected.

Zone Diagnostics

Zone Diagnostics can show temperatures and
issues
1. Ensure the cabinet is powered on, fully booted
up and the main screen is displayed (see Figure
1).
2. Press the tools icon (gear) from the home screen
(see Figure 2).
3. On the next screen press the row of dots at the
bottom of the screen (see Figure 3).
4. The tools options menu is displayed. Press the
Zone Diagnostics button (see Figure 4).
5. After the unit has been running for about 15
minutes the temperatures should cycle from
hot (RED) to normal (GREEN) to cool (BLUE). Any
temperature errors are displayed with "+++" on
the affected zone (see Figure 5).
6. Press the "return" arrow to return to the home
screen (see Figure 6).
7. Press the Press & Go button to view the products
(see Figure 1).