DTM-3200 – OEM Ethernet TSoIP Converter
User Manual
Firmware Revision History
Version
Date
2.3
2014.10.07
2.2
2013.07.11
2.1
2012.10.12
2.0
2012.03.28
Important notice for upgrading to firmware version
An upgrade to firmware version 2.3 is only possible if the firmware version of
your DTM-3200 is v2.0 or higher. If the current firmware version is older than
v2.0, please first upgrade the unit to v2.0.
Changes:
Firmware update v2.3 adds an item to the ASI input settings category: this allows
one to force the module to use a specific input port. The default (which can be
chosen as well) is to auto-detect which input has a signal.
Bug fixes:
IGMP/multicast issue seen after 49 days
Possible failure to sync to ASI input stream
Several other small improvements and bug-fixes
Important notice for upgrading to firmware version
Firmware update v2.2 contains both application and failsafe firmware. Any
interruption of the upgrade process may result in an unusable DTM-3200
module.
An upgrade to firmware version 2.2 is only possible if the firmware version of
your DTM-3200 is v2.0 or v2.1. If the current firmware version is older than
v2.0, please first upgrade the unit to v2.0.
Bug fixes:
Fix for failsafe firmware not starting correctly in specific cases
Important notice for upgrading to firmware version
An upgrade to firmware version 2.1 is only possible if the firmware version of your
DTM-3200 is v2.0. If the current firmware version is older than v2.0, please first
upgrade the unit to v2.0.
Bug fixes:
Ignore a reboot command while the device is rebooting
Stability fixes in the rate estimation algorithm
Important notice for upgrading to firmware version
Firmware update v2.0 contains both application and failsafe firmware. Any
interruption of the upgrade process may result in an unusable DTM-3200 module.
The first boot after this update will take longer than usual, this is normal behavior.
Fixed issues:
DTM-3200 unicasts to all ports of a switching hub
Category 0x81, setting 0x14 'PCR present' does not work
Category 0x81, setting 0x15 'Rate change counter': value is incorrect
Category 0x81, setting 0x19 'Delay factor': value is incorrect
Corruption of IP packet headers leading to occasional packet loss
DHCP client is started twice
The serial command protocol is case-sensitive, should be case insensitive
After extensive communication and reboot the application firmware may get
corrupted
Dtm3200Util user interface locks up when repeatedly sending a setting to
category 0x82, while no Ethernet cable has been attached
Fixed issues related to I2C control:
Accessing other I2C devices while DTM-3200 is processing a command causes
Changes
4
v2.3:
v2.2:
v2.1:
v2.0: