Technical Data; Electromagnetic Compatibility (Emc); Physical Set-Up Of The Board - Addi-Data ADDICOM APCI-7501 Technical Description

4-port serial interface for the pci bus
Table of Contents

Advertisement

Technical description
4

TECHNICAL DATA

4.1

Electromagnetic compatibility (EMC)

The board has been subjected to EMC tests in an accredited laboratory in
accordance with the norms EN50082-2, EN55011, EN55022.
The board complies with the limit values set by the norm EN50082-2 as follows:
ESD .................................................................. 4 kV
Fields ............................................................... 10 V/m
Burst ................................................................. 4 kV
Conducted radio interferences ......................... 10 V
Noise emission
WARNING!
The EMC tests have been carried out in a specific appliance
configuration. We guarantee these limit values only in this
configuration
Consider the following aspects:
- your test program must be able to detect operation errors.
- your system must be set up so that you can find out what caused errors.
4.2

Physical set-up of the board

The board is assembled on a 4-layer printed circuit card.
Breadth:
Weight:
Installation in:
Connection to the peripheral
Chapter 4
131 mm
True value
B class
99 mm
19,2 mm
156 g
PCI 5 V / 32-bit slot
37-pin SUB-D male connector
APCI-7501
Set value
4 kV
10 V/m
2 kV
10 V
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Addicom apci-7501-g

Table of Contents