3 WORK
3.14
28
Installing the 12 V battery
H00386-10
(250 EXC‑F BR)
Warning
Risk of injury Battery acid and battery gases cause
serious chemical burns.
–
Keep 12 V batteries out of the reach of chil-
dren.
–
Wear suitable protective clothing and safety
glasses.
–
Avoid contact with battery acid and battery
gases.
–
Keep sparks or open flames away from the
12 V battery.
–
Only charge 12 V batteries in well-ventilated
rooms.
–
Rinse the affected area immediately with
plenty of water in the event of contact with the
skin.
–
Rinse eyes with water for at least 15 minutes
and consult a doctor immediately if battery
acid and battery gases get into the eyes.
–
Disconnect negative cable
–
Pull back positive terminal cover
positive cable from the 12 V battery.
–
3
Remove screw
.
–
4
Pull holding bracket
tery upwards.
Main work
–
Insert the 12 V battery into the battery compartment with the
terminals facing forward and secure with holding bracket
(EXC‑F EU/AU/US/AR, EXC‑F Six Days)
12 V battery (HJTZ5S-FP-C)
(250 EXC‑F BR)
12 V battery (YTX5L-BS)
–
Mount and tighten screw
Guideline
Remaining screws,
chassis
–
3
Connect positive cable
Guideline
Screw, battery termi-
nal
–
Slide positive terminal cover
–
4
Connect negative cable
1
from the 12 V battery.
2
and disconnect the
forward and remove the 12 V bat-
2
.
M6
10 Nm (7.4 lbf ft)
to the 12 V battery.
M5
2.5 Nm
(1.84 lbf ft)
7
over the positive terminal.
to the 12 V battery.
1
.