256820E
REV. E 613
Printed in U.S.A.
Commander
Strobe Warning Light
Model 371ST-250
Installation and
Maintenance Manual
français...............page 16
español...............página 30
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Commander 371ST-250 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Federal Signal Corporation Commander 371ST-250

  • Page 1 ® Commander Strobe Warning Light Model 371ST-250 Installation and Maintenance Manual 256820E français....page 16 REV. E 613 Printed in U.S.A. español....página 30...
  • Page 2 Warranty Industrial Systems...
  • Page 3: Table Of Contents

    Contents Safety Messages to Installers ..............5 An Overview of Model 371ST-250 ..............6 Unpacking the Light ..................6 Mounting the Light ..................7 ................8 ............... 8 Wiring the Light ..................... 9 Safety Messages to Maintenance Personnel ........... 11 Replacing the Flash Tube ................
  • Page 4 Figures Figure 1 ................8 Figure 2 ..........10 Figure 3 ..............13 Model 371ST-250 Strobe Light...
  • Page 5: Safety Messages To Installers

    Safety Messages to Installers this light. Model 371ST-250 Strobe Light...
  • Page 6: An Overview Of Model 371St-250

    An Overview of Model 371ST-250 ® Unpacking the Light Model 371ST-250 Strobe Light...
  • Page 7: Mounting The Light

    Table 1 225 Vdc to 300 Vdc 0.25 A 10.0 J Peak candela is the maximum light intensity generated by a ECP (Effective Candela) is the intensity that would appear to an observer if the light were burning steadily. Table 2 Mounting the Light Model 371ST-250 Strobe Light...
  • Page 8 Figure 1 PIPE MOUNT PIPE MOUNT SURFACE MOUNT 371ST-250 LIGHT ASSEMBLY GASKET DRILL THREE 9/32" (7.143 mm) HOLES 1" NPT PIPE MOUNTING SURFACE 1/4" FLATWASHERS 1/4" SCREWS 290A3948B Model 371ST-250 Strobe Light...
  • Page 9: Wiring The Light

    next section. Wiring the Light ® ® NOTE: Polarity MUST be observed for proper operation. Model 371ST-250 Strobe Light...
  • Page 10 Figure 2 TURN DIE-CAST RING COUNTER-CLOCKWISE DOME ASSEMBLY TO REMOVE DIE CAST RING SCREWS, #10 HEX HEAD (3) STROBE SPINNING ASSEMBLY GASKET GROUND SCREW BASE CONDUIT PLUG (USER SUPPLIED) CONDUIT HUB CONDUIT NUT 290A3949B (USER SUPPLIED) (USER SUPPLIED) Model 371ST-250 Strobe Light...
  • Page 11: Safety Messages To Maintenance Personnel

    Safety Messages to Maintenance Personnel turned off. local codes. Model 371ST-250 Strobe Light...
  • Page 12: Replacing The Flash Tube

    Replacing the Flash Tube Model 371ST-250 Strobe Light...
  • Page 13 Figure 3 DOME ASSEMBLY DIE CAST RING TURN DIE CAST RING COUNTER-CLOCKWISE FRESNEL LENS TO REMOVE FLASH TUBE #8 SCREWS (2) STROBE SPINNING ASSEMBLY BASE 290A3950B Model 371ST-250 Strobe Light...
  • Page 14: Cleaning The Dome

    Cleaning the Dome Getting Service, Assistance, and Parts Model 371ST-250 Strobe Light...
  • Page 15: Table 3

    Table 3 Description Part Number Table 4 Accessories Description Part Number Model 371ST-250 Strobe Light...
  • Page 16 Garantie Systèmes industriels Model 371ST-250 Strobe Light...
  • Page 17 Table des matières Messages de sécurité destinés aux installateurs ........19 Description générale du modèle 371ST-250 ..........20 Déballage de la lumière ................20 Montage de la lumière ................21 ............... 22 ............... 22 Câblage de la lumière ................. 23 Messages de sécurité...
  • Page 18 Illustrations Illustration 1 ..............22 Illustration 2 ........24 Illustration 3 ..........Model 371ST-250 Strobe Light...
  • Page 19: Messages De Sécurité Destinés Aux Installateurs

    Messages de sécurité destinés aux installateurs AVERTISSEMENT tension. fonctionnement. Model 371ST-250 Strobe Light...
  • Page 20: Description Générale Du Modèle 371St-250

    Description générale du modèle 371ST-250 ® Déballage de la lumière Model 371ST-250 Strobe Light...
  • Page 21: Montage De La Lumière

    Tableau 1 10 000 heures Le candela de pic est l’intensité lumineuse maximale générée par une lampe clignotante pendant son impulsion lumineuse. L’ECP (puissance lumineuse effective) est l’intensité qui serait visible pour un observateur si la lumière fournissait un éclairage constant.
  • Page 22 Illustration 1 MONTAGE MONTAGE EN INSTALLATION SUR TUBE SAILLIE LUMINEUSE 371ST-250 JOINT D’ÉTANCHÉITÉ PERCEZ TROIS TROUS TUBE À DE 7,143 MM (9/32 PO.) FILETAGE CONIQUE 25,4 MM (1 PO.) SURFACE DE MONTAGE RONDELLES PLATES 6,35 MM (1/4 PO.) VIS 6,35 MM (1/4 PO.) 290A3948B Model 371ST-250 Strobe Light...
  • Page 23: Câblage De La Lumière

    fournies. Câblage de la lumière AVERTISSEMENT montre. ® ® REMARQUE : la polarité DOIT être respectée pour un fonctionnement approprié. Model 371ST-250 Strobe Light...
  • Page 24 Illustration 2 TOURNEZ LA BAGUE EN FONTE DANS LE SENS INVERSE DES AIGUILLES DÔME D’UNE MONTRE POUR LA RETIRER BAGUE EN FONTE VIS, TÊTE HEXAGONALE N° 10 (3) ENSEMBLE ROTATIF POUR STROBOSCOPE JOINT D’ÉTANCHÉITÉ VIS DE TERRE BASE BOUCHON DE CONDUIT (FOURNI PAR L’UTILISATEUR) CONCENTRATEUR DE CONDUIT ÉCROU DE CONDUIT...
  • Page 25: Messages De Sécurité Destinés Au Personnel D'entretien

    Messages de sécurité destinés au personnel d’entretien qu’aux codes locaux. Model 371ST-250 Strobe Light...
  • Page 26: Remplacement De La Lampe-Éclair

    Remplacement de la lampe-éclair AVERTISSEMENT AVERTISSEMENT Model 371ST-250 Strobe Light...
  • Page 27 ATTENTION Illustration 3 DÔME BAGUE EN FONTE TOURNEZ LA BAGUE EN FONTE DANS LE SENS LENTILLE INVERSE DES AIGUILLES DE FRESNEL D’UNE MONTRE POUR LA RETIRER LAMPE-ÉCLAIR VIS N° 8 (2) ENSEMBLE ROTATIF POUR STROBOSCOPE BASE 290A3950B Model 371ST-250 Strobe Light...
  • Page 28: Nettoyage Du Dôme

    ATTENTION dans la douille. Nettoyage du dôme Entretien, assistance et pièces Model 371ST-250 Strobe Light...
  • Page 29: Tableau 1

    Tableau 3 Description Numéro de pièce Tableau 4 Accessoires Description Numéro de pièce Model 371ST-250 Strobe Light...
  • Page 30 Garantía Sistemas Industriales Model 371ST-250 Strobe Light...
  • Page 31 Contents Mensajes de seguridad para los instaladores .......... 33 Descripción del Modelo 371ST-250 ............34 Desembalaje de la luz ................. 34 Montaje de la luz ..................35 ..............36 ............. 36 Cableado de la luz ..................37 Mensajes de seguridad al personal de mantenimiento ......39 Reemplazo del tubo de parpadeo ..............
  • Page 32 Figures Figura 1 ..............36 Figura 2 ..........38 Figura 3 ........... 41 Model 371ST-250 Strobe Light...
  • Page 33: Mensajes De Seguridad Para Los Instaladores

    Mensajes de seguridad para los instaladores ADVERTENCIA funcione correctamente. o incluso la muerte. Model 371ST-250 Strobe Light...
  • Page 34: Descripción Del Modelo 371St-250

    Descripción del Modelo 371ST-250 ® Desembalaje de la luz Model 371ST-250 Strobe Light...
  • Page 35: Montaje De La Luz

    Tabla 1 10 000 horas La candela pico es la intensidad máxima de la luz generada por una luz parpadeante durante su impulso luminoso. ECP (Candela efectiva) es la intensidad que aparecería para un observador si la luz se mantuviera encendida permanentemente. Tabla 2 Montaje de la luz Model 371ST-250 Strobe Light...
  • Page 36 Figura 1 MONTAJE EN MONTAJE EN TUBO UNIDAD DE SUPERFICIE LUZ 371ST-250 JUNTA PERFORAR TRES ORIFICIOS DE 7,143 mm (9/32") TUBO NPT DE 1" SUPERFICIE DE MONTAJE ARANDELAS PLANAS DE 1/4" TORNILLOS 290A3948B DE 1/4" Model 371ST-250 Strobe Light...
  • Page 37: Cableado De La Luz

    Cableado de la luz ADVERTENCIA ® ® NOTA: DEBE observarse la polaridad para un funcionamiento correcto. Model 371ST-250 Strobe Light...
  • Page 38 Figura 2 GIRE EL ANILLO DE FUNDICIÓN EN SENTIDO UNIDAD DE ANTIHORARIO PARA RETIRAR LA CÚPULA ANILLO DE FUNDICIÓN TORNILLOS, N.° 10, CABEZA HEXAGONAL (3) UNIDAD DE GIRO ESTROBOSCÓPICO JUNTA TORNILLO DE PUESTA A TIERRA BASE TAPÓN DE CONDUCTOS (PROVISTO POR EL USUARIO) CENTRO DE CONDUCTOS TUERCA DE CONDUCTOS 290A3949B...
  • Page 39: Mensajes De Seguridad Al Personal De Mantenimiento

    funcionamiento correcto. Mensajes de seguridad al personal de mantenimiento funcionamiento este sistema. alteraciones a las unidades. o incluso la muerte. Model 371ST-250 Strobe Light...
  • Page 40: Reemplazo Del Tubo De Parpadeo

    Reemplazo del tubo de parpadeo ADVERTENCIA ADVERTENCIA Model 371ST-250 Strobe Light...
  • Page 41 PRECAUCIÓN Figura 3 UNIDAD DE LA CÚPULA ANILLO DE FUNDICIÓN GIRE EL ANILLO DE FUNDICIÓN EN SENTIDO LENTE ANTIHORARIO PARA RETIRAR FRESNEL TUBO DE PARPADEO TORNILLOS N.° 8 (2) UNIDAD DE GIRO ESTROBOSCÓPICO BASE 290A3950B Model 371ST-250 Strobe Light...
  • Page 42: Limpieza De La Cúpula

    PRECAUCIÓN el enchufe. Limpieza de la cúpula Obtención de servicio, asistencia y piezas Model 371ST-250 Strobe Light...
  • Page 43: Tabla 3

    Tabla 3 Descripción Número de pieza Tabla 4 Accesorios Descripción Número de pieza Model 371ST-250 Strobe Light...
  • Page 44 ¡ ¢ £ ¤ ¥ ¦ § ¦ ¨ © © ¨...