Page 1
HDMI® 4x4 4K M A T R I X Supports 4K@60Hz, 4:4:4 Chroma and HDR Vanco Part Number EVMX4K44 HDMI® 4 x 4 4K Matrix Selector Switch www.vanco1.com • 800.626.6445...
Page 2
DEAR CUSTOMER Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully before connecting, operating or adjusting this product. Please keep this manual for future reference. This product is 100% inspected and tested in the United States to verify HDMI performance parameters.
INTRODUCTION The Evolution by Vanco EVMX4K44 4x4 Matrix with IR, RS-232, and IP control, allows 4 HDMI sources to be distributed to up to 4 displays simultaneously. Have multiple sources displayed simultaneously on any display or have a single source split to multiple displays, flexibility for the perfect solution.
PANEL DESCRIPTIONS 1. Firmware: Micro USB port for updating firmware when applicable 2. LCD Screen - Displays Input/Output status 3. IR Sensor - receives IR signal from included remote 4. LCD Power Indicator 5. INPUT Selection Buttons: Select input to send to any output 6.
CONNECTION DIAGRAM CONNECT AND OPERATE 1. Connect up to 4 sources such as a Blu-Ray Player, game console, A/V Receiver, Cable or Satellite Receiver, etc. to the HDMI inputs on the unit. 2. Connect up to 4 displays such as an HDTV, Projector, etc. to the HDMI outputs on the unit. 3.
FRONT PANEL CONTROL Input/Output Switching The front panel features four input selection buttons and four output selection buttons for manual switching: To send one input signal to any single output: Example Input 1 to Output 3 Press S1 + D3 To send one input signal to multiple outputs: Example: Input 2 to Output 3 and 4 Press S2 + D3 + D4...
REMOTE CONTROL Standby button, press to turn on or off the unit, note that the unit will not turn completely off, and will go into standby mode 2. INPUTS: Select any input in order to send to any output 3. OUTPUTS: Select the desired output to send the input signal to 4.
RS-232 CONTROL Set the parameters (baud rate, data bit, stop bit and parity bit) correctly to ensure reliable RS-232 control. Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none • “[“, “]” in the commands are for easy recognition only and not necessary in real operations. Other symbols including “.”, “,”, “/”, “%”, “;”, “^”.
Page 10
Controlled by single PC Connect a computer to the TCP/IP port of the Matrix Switcher and set its network segment to the same as the default IP of the Matrix Switcher (192.168.0.178). Change the IP of the PC Controlled by PC(s) in LAN The Matrix Switcher can be connected to a router or switch.
USER INTERFACE The EVMX4K44 has a built-in UI (User Interface) for convenient TCP/IP control. The UI allows switching, EDID adjustment, network changes etc. Access the UI interface through any one of the following methods: Access through web browser: Type the default IP of 192.168.0.178 in any browser of a connected device, wired or wireless.
Page 12
Main Tab The main tab allows for switching inputs to outputs, using a grid format, simply select the input and output combination desired. The button matrix displays every possible connection between every input and output, users can carry on the connections by clicking corresponding button.
Interface Tab The interface tab allows for changes to the name of the matrix switcher, the LCD readout on the front panel, and also allows for changing the name of the inputs and outputs for easier input/output switching. Configuration Tab The configuration tab allows for switching on/off the SPDIF digital audio output for every output and also manages EDID.
Page 14
EDID Copy: One or multiple inputs received EDID info from one specific output. EDID Setting: Select the built-in EDID for every input. Choose from a list of default EDID combinations. www.vanco1.com...
Network Tab The network tab allows for IP and other network info changes. Be sure to note down this info and save. UI Update The UI for the Matrix Switcher supports online updating, enter the following URL: http://192.168.0.178:100 in any browser. Type the username and password (the same as the UI log-in settings, modified password will be available only after rebooting) to log in the configuration interface.
TCP/IP Port Configuration IP address, subnet mask, and Gateway of the Matrix Switcher can be modified via UI from the above description, additionally the IP port, including IP reset, password reset, and IP module firmware update can also be completed on the WebServer. Enter the same URL (Default: 192.168.0.178:100, changeable) in your browser.
Page 17
Problems Causes Solutions Color loss or no video signal The connecting cables may Check whether the cables are connected output in HDMI display not be connected correctly or correctly and in working condition. it may be broken. Fail or lose connection. Make sure the connection is good.
If repairs are needed during the warranty period the purchaser will be required to provide a sales receipt/sales invoice or other acceptable proof of purchase to the seller of this equipment. The seller will then contact Vanco regarding warranty repair or replacement.
TECHNICAL SUPPORT In case of problems, please contact Vanco Technical Support by dialing 1-800-626-6445. You can also email technical support issues to techsupport@vanco1.com. When calling, please have the Model Number, Serial Number (affixed to the bottom of the unit) and Invoice available for reference during the call.
Need help?
Do you have a question about the Evolution EVMX4K44 and is the answer not in the manual?