Electric Connections - Leb Electronics STONE 230 Instructions And Warnings For Installation, Use And Maintenance

Underground gear motor for wings gates
Hide thumbs Also See for STONE 230:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH

ELECTRIC CONNECTIONS

Warnings
- The gearmotor must be connected but to a control unit
manufactured by the company LEB.
- All connection operations must be performed without electric
voltage.
Power supply cable
- From the electric motor comes out four wires (230Vac -
or two wires (24Vdc - STONE 24).
- In the following table the data concerning the power supply cable,
required for the connection to the control unit, are reported.
STONE 230
Cable 4x1,5 mm
Common
Motor OPEN
Motor CLOSE
Ground
Capacitor connection
- In the gearmotor STONE 230 connect the capacitor between the
black wire (Open) and the brown wire (Close) of the electric engine.
Limit switches cable
The device is equipped with two magnetic Limit switches. From the
Limit switches block three wires come out. In the following table the
data concerning the Limit switches cable, required for the connection
to the control board, are reported.
Cable 3 x 1,5 mm
Common
Limit switch OPENING
Limit switch CLOSING
STONE 24
Color
Cable 2x1,5 mm
Blue
Positive motor
Black
Negative motor
Brown
Yellow-Green
- 21 -
STONE 230
Color
Red or Green
Black or Brown
Colour
Blue
Black
Brown
)

Hide quick links: