Leb Electronics STONE 230 Instructions And Warnings For Installation, Use And Maintenance page 19

Underground gear motor for wings gates
Hide thumbs Also See for STONE 230:
Table of Contents

Advertisement

Available languages

Available languages

Limit switches set up
Warning : for complete safety, the mechanical stops with rubber
cap (floor stops) must be fitted in opening and closing of the
gate in order to define the extreme points of the run.
- Connect the cable coming from the installation to the Limit switches
cable piece by means of heat shrinkable tubing (total insulation).
- Make sure that the gearmotor isn't unlocked.
- Set up the "
Step-by-Step
- Start the gate run. As soon as the gate reaches the complete
opening, stop the gate by means of the remote control.
- With a screwdriver, move the magnet of the opening Limit switch
until the LED on the control unit goes off (fig. 13).
- Start the gate closing. As soon as the gate reaches the complete
closing, stop the gate by means of the remote control.
- With a screwdriver, move the magnet of the closing Limit switch
until the LED on the control unit goes off (fig. 13).
Fig. 13
Magnet
" operation mode on the electronic card.