Advertisement

Quick Links

NEV 400 LSN Power supply
ISP‑NEV400‑120
en
Installation manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch NEV 400 LSN

  • Page 1 NEV 400 LSN Power supply ISP‑NEV400‑120 Installation manual...
  • Page 3: Table Of Contents

    NEV 400 LSN Power Table of contents | en supply Table of contents Safety Short information System overview Installation Preparations Removing the enclosure knockouts Installing the tamper switch rail Installing the enclosure Installing the power supply and the AC terminal block...
  • Page 4: Safety

    NEV 400 LSN Power en | Safety supply Safety Danger! Battery Injuries due to electric shock, fire or explosion are possible if the battery is handled or connected incorrectly. – Always handle the battery carefully and replace it carefully. –...
  • Page 5 NEV 400 LSN Power Safety | en supply – Only qualified installers/service personnel are allowed to install and maintain this system. Danger! Electricity Injuries due to electricity are possible if the system is not grounded correctly. – Ensure to ground the system correctly.
  • Page 6 NEV 400 LSN Power en | Safety supply – Place the system inside the monitored area on a stable surface. – Once the system is tested and ready to use, secure the enclosure door with screws. Caution! Maintenance Damage or malfunction of the system is possible if it is not maintained on a regular basis.
  • Page 7: Short Information

    Short information | en supply Short information The NEV 400 LSN provides a remote power supply and is installed offside a control panel. Trouble and tamper events are transmitted via LSN (local security network). This manual contains information on how to install the NEV 400 LSN.
  • Page 8: System Overview

    NEV 400 LSN Power en | System overview supply System overview The NEV 400 LSN contains the following components: Figure 3.1: NEV 400 LSN system overview Element Description ICP-MAP0120 expansion enclosure ISP-PCBA-EMIL IMS-RM relay module (optional) ICP-MAP0021 accessory mounting plate EMIL...
  • Page 9 NEV 400 LSN Power System overview | en supply Element Description ICP-MAP0055 expansion enclosure tamper switch Thermistor Batteries IPP-MAP0005-2 MAP power supply 28V/150W AC terminal block Bosch Security Systems B.V. 2019-11 | 04 | F.01U.309.346...
  • Page 10: Installation

    NEV 400 LSN Power en | Installation supply Installation This chapter contains information on how to install the components of the NEV 400 LSN. Danger! Electrostatic discharge Injuries and damage of electronic components are possible due to electrostatic discharge. –...
  • Page 11: Preparations

    NEV 400 LSN Power Installation | en supply Preparations – Use proper anchor and screw sets when installing the enclosure on surfaces. Refer to the drill template for detailed instructions. – Ensure that there is enough free space to the left of the enclosure so that the enclosure door has full range of motion.
  • Page 12: Removing The Enclosure Knockouts

    NEV 400 LSN Power en | Installation supply Removing the enclosure knockouts Unhinge and remove the enclosure door and set it aside. Remove the enclosure knockouts in the order shown in the figure below. Figure 4.1: Removing the enclosure knockouts Element...
  • Page 13: Installing The Tamper Switch Rail

    NEV 400 LSN Power Installation | en supply Installing the tamper switch rail Remove the tamper switch rail from the package. Mount the tamper switch rail to the inner right side of the enclosure as shown in the figure below.
  • Page 14: Installing The Enclosure

    NEV 400 LSN Power en | Installation supply Installing the enclosure Notice! Ensure that there is enough free space to the left of the enclosure so that the enclosure door has full range of motion. - For a fully opened door, at least 460 mm (18 in) is required.
  • Page 15 NEV 400 LSN Power Installation | en supply Figure 4.3: Installing the wall tamper plug Bosch Security Systems B.V. 2019-11 | 04 | F.01U.309.346...
  • Page 16 NEV 400 LSN Power en | Installation supply Mounting the enclosure Mount the enclosure to the intended surface using suitable screws and anchors (not supplied). Use the mounting holes as shown in the figure below. Ensure that all screws are tight and that the enclosure is securely fastened to the mounting surface.
  • Page 17: Installing The Power Supply And The Ac Terminal Block

    NEV 400 LSN Power Installation | en supply Installing the power supply and the AC terminal block Caution! Debris Damage to the power supply due to debris during the installation is possible. – To prevent damage to the power supply during installation, fit the supplied protective dust cover label on top of the power supply before installing it.
  • Page 18 NEV 400 LSN Power en | Installation supply Figure 4.5: Installing the power supply 2019-11 | 04 | F.01U.309.346 Bosch Security Systems B.V.
  • Page 19 NEV 400 LSN Power Installation | en supply Installing the AC terminal block Installing the AC terminal block Mount the AC terminal block to the enclosure back wall into the corresponding mounting holes as shown in the figure below and secure it with the supplied screws (1).
  • Page 20: Installing The Map Accessory Mounting Plate

    NEV 400 LSN Power en | Installation supply Installing the MAP accessory mounting plate Align the earth ground stud on the MAP accessory mounting plate with the earth ground hole on the top mounting rail in the upper right side of the enclosure wall as shown in the figure below.
  • Page 21 NEV 400 LSN Power Installation | en supply Figure 4.8: Installing the MAP accessory mounting plate - backview Bosch Security Systems B.V. 2019-11 | 04 | F.01U.309.346...
  • Page 22: Installing A 12 V Converter (Optional)

    NEV 400 LSN Power en | Installation supply Installing a 12 V converter (optional) It is optional to install up to two 12 V converters onto the MAP accessory mounting plate. Mount one or two 12 V converters onto the MAP accessory mounting plate as shown in the figure below.
  • Page 23 NEV 400 LSN Power Installation | en supply For an overview of the cabling, refer to Cabling overview, page Connect two wires to each of the terminal blocks of the 12 V converters as shown in the figure above. Connect the two wires that lead to the input terminal block of the 12 V converter to terminal 1 and 2 of the EMIL expansion module.
  • Page 24: Installing A Siv 28 Fuse Plate (Optional)

    NEV 400 LSN Power en | Installation supply Installing a SIV 28 fuse plate (optional) It is optional to install a SVI 28 fuse plate onto the MAP accessory mounting plate. Mount the SIV 28 onto the MAP accessory mounting plate as shown in the figure below.
  • Page 25: Installing The Emil Expansion Module

    NEV 400 LSN Power Installation | en supply For an overview of the cabling, refer to Cabling overview, page Connect the prewired cable supplied with the SIV 28 to the terminal block of the SIV 28. Clip off the connector from the other end of the cable and connect the two wires to B and R of the terminal block B of the power supply.
  • Page 26: Installing A Relay Module (Optional)

    NEV 400 LSN Power en | Installation supply Fasten the MAP accessory mounting plate EMIL using three screws (supplied). 4.10 Installing a relay module (optional) Insert the two corner distance bolts (supplied) into the designated left holes on the upper right side of the MAP accessory mounting plate EMIL and fasten the screws from underneath.
  • Page 27: Installing The Enclosure Lockset

    NEV 400 LSN Power Installation | en supply 4.11 Installing the enclosure lockset Remove the lockset knockout from the enclosure door as shown in the figure below (1). Insert the lockset into the opening on the enclosure door as shown in the figure below (2).
  • Page 28: Cabling

    NEV 400 LSN Power en | Cabling supply Cabling This chapter contains information on how to wire the components of the NEV 400 LSN. Danger! Electrostatic discharge Injuries and damage of electronic components are possible due to electrostatic discharge. –...
  • Page 29: Cabling Overview

    NEV 400 LSN Power Cabling | en supply Cabling overview This chapter shows an overview of the cabling of NEV 400 LSN. AUX 12 VDC 5x AUX 28 VDC ICP-MAP 0017 (optional) SIV 28 (optional) AUX 1 28 VDC aLSN1...
  • Page 30: Connecting The Thermistor

    NEV 400 LSN Power en | Cabling supply Connecting the thermistor For an overview of the cabling, refer to Cabling overview, page Connect the thermistor cable (supplied, P/N F01U074759) to terminal block 3 of the power supply. Mount the thermistor cable around the power supply as shown in the figure below.
  • Page 31 NEV 400 LSN Power Cabling | en supply Figure 5.3: Tamper switch extension piece Slide the tamper switch onto the rail as shown in the figure below. Figure 5.4: Installing the tamper switch Clip off the connector from the cable of the tamper switch as shown in the figure below.
  • Page 32: Connecting The Emil Expansion Module To The Power

    NEV 400 LSN Power en | Cabling supply Figure 5.5: Tamper switch connection Connecting the EMIL expansion module to the power supply For an overview of the cabling, refer to Cabling overview, page Connect two wires to terminal 5 and 6 of the EMIL expansion module.
  • Page 33: Connecting The Lsn

    NEV 400 LSN Power Cabling | en supply Connecting AUX 2 (28 VDC) Connect two wires to B and R of the terminal block A of the power supply Use the other end of the wires as AUX output 2.
  • Page 34: Initial Set-Up And Programming

    NEV 400 LSN Power en | Initial set-up and programming supply Initial set-up and programming Initial set-up Before initial set-up, check the following: – Are all cables connected correctly? – Is the power supply in correct operation after the AC mains...
  • Page 35 NEV 400 LSN Power Initial set-up and programming | en supply Figure 6.1: Connecting the batteries Danger! Battery Injuries due to electric shock, fire or explosion are possible if the battery is handled or connected incorrectly. – Always handle the battery carefully and replace it carefully.
  • Page 36: Programming

    NEV 400 LSN Power en | Initial set-up and programming supply Programming Programming instructions for the EMIL expansion module in RPS for MAP Device Name Property EMIL NEV 400 Use Coupler expans Tamper Switch = modul Input Name Point Type...
  • Page 37 NEV 400 LSN Power Initial set-up and programming | en supply S 3* LED Fuse Failure LED Activate Output 3 on Input 3 free * optional Programming instructions for the EMIL expansion module in Winpara Input Short Info Message Mode...
  • Page 38 NEV 400 LSN Power en | Initial set-up and programming supply PL 6 free Output Output Behavior LED1* Activate LED 1 when PL1 triggered LED2* Activate LED 2 when PL2 triggered Cpoint Activate Cpoint when PL3 triggered free * optional...
  • Page 39 NEV 400 LSN Power Initial set-up and programming | en supply PL 2 Battery Malfunctio Stand EMIL- Failure OUT2* PL 3* Fuse Malfunctio Stand EMIL- Failure OUT3* PL 4 Tamper Sabotage Conta None Input PL 5 free free PL 6...
  • Page 40: Troubleshooting

    NEV 400 LSN Power en | Troubleshooting supply Troubleshooting Problem Reason Solution BATT 1 indicator is Battery is missing Check battery Connect battery or replace battery BATT 1 indictor is Battery low Check battery blinking Wait for battery to charge...
  • Page 41: Maintenance

    NEV 400 LSN Power Maintenance | en supply Maintenance Maintenance and inspection work must be carried out at defined intervals and by corresponding expert personnel. The regulations of DIN VDE 0833 apply additionally for all work of this kind. Danger!
  • Page 42: Technical Data

    NEV 400 LSN Power en | Technical data supply Technical data Electrical Rated voltage in VDC 28 ± 1 Minimum operating voltage in VDC Maximum operating voltage in VDC Minimum output voltage in VDC Maximum output voltage in VDC Rated current in mA...
  • Page 44 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2019...

Table of Contents