100637 - 9000W PORTABLE GENERATOR

Generator Battery

Your generator is equipped with an automatic battery charging
circuit that charges the battery while the engine is running.
The battery will maintain a proper charge if the unit is used on
a regular basis (about once every two weeks). If it is used less
frequently, the battery should be connected to a trickle charger
or battery maintainer (not included) to keep the battery properly
charged.
Maximum charging rate should not exceed 1.5 amps. Follow
the instructions included with the battery charger. The battery
should be fully charged at least once per month. If the battery is
not able to start the engine, it can be started by manually pulling
the engine recoil cord. If the battery voltage is extremely low, the
charging circuit may not be able to re-charge the battery. In this
case, the battery must be connected to a standard automotive
style battery charger for re-charging before it can be used.
Disconnect the Battery
1. Remove the protective cover from the black (–) battery lead.
2. Disconnect the black (–) lead from the black (–) terminal on
the battery and store the cap screw and nut.
3. Repeat steps 1-2 for the red (+) battery lead.
4. Store the battery in a cool, dry place.
Charge the Battery
For a generator equipped with batteries for electric starting,
proper battery maintenance and storage should be followed.
A trickle charger or battery maintainer should be used to charge
the battery while the generator is in storage. Maximum charging
rate should not exceed 1.5 amps. Follow the instructions included
with the trickle charger or battery maintainer. The battery should
be fully charged at least once per month.

Maintenance Schedule

Follow the service intervals indicated in the following maintenance
schedule.
Service your generator more frequently when operating in adverse
conditions.
Contact our Technical Support Team at 1-877-338-0999 to locate
the nearest CPE certified service dealer for your generator or
engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
— Check oil level
— Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN)
— Change oil
EVERY 50 HOURS OR ANNUALLY
— Clean air filter
— Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY
— Change oil
— Clean/adjust spark plug
— Clean spark arrestor
— Clean fuel valve filter*
EVERY 250 HOURS
— Clean combustion chamber*
— Check/adjust valve clearance*
EVERY 3 YEARS
— Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certified service
centers.
26
MAINTENANCE