• Press ↓ to view the Port B Baud Rate screen. Press ← and use the ↑ and ↓ keys to set
the baud rate to match the Baud Rate of the RTK Bridge-X. (38,400 is
recommended)
• Return to the Home Display screen, then navigate to the Output Config screen and
verify the Port B Baud Rate matches what is set in the Intuicom RTK Bridge-X
(38400 recommended)
• Set the GGA message to output at an Interval of 001.00
Once this has been completed, you should be able to verify the Raven Phoenix 300 is
receiving RTK corrections from the Intuicom RTK Bridge-X by the following:
• System Ok on the screen
• Letter "R" in front of the 3, this confirms an RTK fixed position.
For Technical Support of the RTK Bridge-X, Intuicom recommends
"Intuicom Remote Support", please contact Intuicom for details on this real-