  • Page 1 Log boiler for 1/2 m logs englisch Operating instructions BMK-A-00-00-00-02-BAEN EN-B30-004-V06-0412-V3.0...
  • Page 2 We are always looking to improve our products and documentation. Any ideas and suggestions you may have will be gratefully received. GUNTAMATIC Heiztechnik GmbH a Georg Fischer Group Company Bruck 7 A-4722 PEUERBACH Tel: 0043 (0) 7276 / 2441-0 Fax: 0043 (0) 7276 / 3031 E-mail: info@guntamatic.com...
  • Page 3: Table Of Contents

    BMK Operating Instructions Contents Page BMK-C-00-00-00-01-BAEN Introduction............5 Brief description Type approval Further information Important notes............6 Intended use Operating the heating system Guarantee and liability Safety instructions System components..........10 Safety systems...........11 Description of control panel ......12 Overview of menu and levels......13 Information level House level 6.2.1...
  • Page 4 BMK Operating Instructions Contents Page Operating the heating system......30 Commissioning Heating system checks Fuel quality Fuel setting Heating-up procedure 8.5.1 Manual heating up 8.5.2 Automatic heating up Heating operation Emptying the ash Cleaning and care ..........35 Interim cleaning Complete cleaning 10 Rectifying faults ..........37 11 Replacing fuses ..........38...
  • Page 5: Introduction

    Even the best boiler cannot operate effectively without proper care and maintenance, so please read through these instructions carefully and have your appliance commissioned by an engineer authorised by GUNTAMATIC. Most importantly, you should follow the safety instructions in Section 2.
  • Page 6: Important Notes

    BMK Operating Instructions Important notes BS-02-00-00-00-01-BAEN Your boiler has been designed and produced in accordance with the latest technical advances and all applicable safety regulations. Nevertheless incorrect operation, the use of unapproved fuels or the failure to carry out necessary maintenance and repairs can result in personal injury or damage to property.
  • Page 7: Safety Instructions

    BMK Operating Instructions Safety instructions BS-02-04-00-00-01-BAEN To prevent accidents, small children should not be allowed into the boiler room or the fuel storeroom. Please follow the safety instructions below. By doing so, you will protect yourself and prevent damage to your heating system. Power switch BS-02-04-00-01-01-BAEN Note:...
  • Page 8 BMK Operating Instructions Servicing work BS-02-04-00-06-01-BAEN Note: Service the boiler regularly or make use of our Customer Service. Emptying ash BS-02-04-00-07-01-BAEN Danger: Glowing embers can cause fires. The ash should only be removed from the boiler or stored in non-combustible containers.
  • Page 9 BMK Operating Instructions Heating operation SY-02-04-00-01-01-BAEN Danger: Risk of detonation. During normal heating operation of the boiler, the boiler doors and the inspection cover must not be opened. In an emergency: Cool skin burns with cold running water. Administer first aid. Call the duty doctor.
  • Page 10: System Components

    BMK Operating Instructions System components BS-03-00-00-00-01-BAEN Cutaway diagram of BMK BMK-03-01-00-00-01-BAEN 1. Large fuel box 2. Close-mesh hot grate 3. Ash box 4. Regulated, preheated secondary air 5. Regulated, preheated primary air 6. Turbo combustion chamber 7. Helix baffles 8. Cleaning lever 9.
  • Page 11: Safety Systems

    BMK Operating Instructions Safety systems BS-04-00-00-00-01-BAEN To prevent the boiler overheating, the controller reduces the heat output in certain situations. If the boiler still threatens to overheat, the controller responds according to a set of defined safety levels. Safety level 1 SY-04-00-00-01-01-BAEN Boiler temperature 87°...
  • Page 12: Description Of Control Panel

    BMK Operating Instructions Control panel description BS-05-00-00-00-01-BAEN The appliance has a large touch-screen control panel with a menu-based interface. All setting and query options are shown on the display. All settings can be entered by pressing the "buttons" on the touch screen. Any system messages are displayed on the screen.
  • Page 13: Overview Of Menu And Levels

    Commissioning menu. DHW1 Parameters Changes to the settings on the Service and • • • • DHW2 Parameters Parameters levels may only be made with the agreement of GUNTAMATIC. HP0 parameters System settings Layout of touch-screen display BS-06-00-00-01-01-BAEN Header...
  • Page 14: Information Level

    BMK Operating Instructions Information level (User) BMK-06-01-00-00-01-BAEN You use the "DOWN" and "UP" buttons to navigate through the Information Level menu. Fault → highest priority Plain-language fault messages are displayed showing date and time of occurrence Fault is acknowledged by pressing "Quit" button Information level →...
  • Page 15: House Level

    BMK Operating Instructions House level (User) BMK-06-02-00-00-01-BAEN All heating programmes and menus are listed and described below: Central heating and hot water switched off Heating and hot water on as per timer programme Hot water as per timer programme DHW summer →...
  • Page 16: User Level

    BMK Operating Instructions User level (user) BMK-06-03-00-00-01-BAEN Depending on the system configuration, the menu levels and submenus may contain different items. Heating Circuit 0 menu → Timer controlled pump heating circuit on HCC 0 Heating Circuit 1 menu → Timer controlled mixer heating circuit on HCC 0 Heating Circuit 2 menu →...
  • Page 17: Heating Circuit Menu

    BMK Operating Instructions 6.3.1 Heating Circuit menu (User) BS-06-03-01-00-01-BAEN The Heating Circuit menu allows you to enter the settings for the various heating circuits. Heating circuit control status Facility for setting heating and low-temperature times Facility for setting daytime required temperature Facility for setting night-time required temperature Facility for setting room effect/thermostat function Facility for setting heating characteristic...
  • Page 18: User Menu

    Detail View. No settings can be made on this menu. Its primary purpose is to aid telephone diagnosis of possible fault causes and to assist the GUNTAMATIC engineer with fault rectification. 6.3.5 Date/Time menu (User)
  • Page 19: Service Level

    (Expert) BS-06-04-00-00-01-BAEN CODE entry required. Changes to the settings on the Service Level may only be made with the agreement of GUNTAMATIC or an authorised GUNTAMATIC engineer. Service menu Reset data → Caution: All system settings may be lost. Service menu Fault screen →...
  • Page 20: Service Menu Commissioning

    BMK Operating Instructions 6.4.3 Commissioning Service menu (Expert) BMK-06-04-01-00-01-BAEN All system components present can be programmed and activated from the service menu Commissioning. For setting boiler type For setting boiler output → stated on rating plate For setting speed control →...
  • Page 21: Service Menu Heating Circuit/Screed Prog. Parameters

    BMK Operating Instructions Options → None No room stat connected → RFF Analogue room stat is connected → RS Full Digital room controller is connected (facility for setting all heating circuits) → RS HC Digital room controller is connected (facility for setting assigned heating circuit only) Options →...
  • Page 22: Service Menu Hot Water Parameters

    BMK Operating Instructions 6.4.5 Hot water parameters Service menu (Expert) SY-06-04-02-00-01-BAEN Facility for setting hot water parameters Hot water circuit operating mode Facility for setting hot water hysteresis → Hot water cylinder recharging Enabling temperature for cylinder charging pump → CCP 0 If the temperature in the hot water cylinder falls 10°C (hysteresis) below the required temperature, the hot water cylinder is heated up again;...
  • Page 23: Service Menu System Settings

    BMK Operating Instructions 6.4.7 System Settings Service menu (Expert) BMK-06-04-04-00-01-BAEN Facility for setting special boiler and system parameters For setting system type → stated on rating plate For setting boiler type → stated on rating plate For setting speed control →...
  • Page 24: User Settings

    BMK Operating Instructions User Settings BS-07-00-00-00-01-BAEN Activating a heating programme SY-07-01-00-00-01-BAEN To set the "NORMAL" programme, proceed as set out below, step by step: 1) → Touch the touch screen with your finger 2) → Press the "House level" button The programme currently selected, "Off", is shown in the header 3) →...
  • Page 25: Deactivating A Heating Programme

    BMK Operating Instructions Deactivating a heating programme SY-07-02-00-00-01-BAEN To set the "NORMAL" programme to "OFF", proceed as set out below, step by step: 1) → Touch the touch screen with your finger 2) → Press the "House level" button The programme currently selected, "Normal", is shown in the header 3) →...
  • Page 26: Setting A Timer Programme

    BMK Operating Instructions Setting a timer programme SY-07-03-00-00-01-BAEN The heating circuits/charging pumps can only be called into action during the times enabled in the timer programme. The example set out below illustrates programming the timer programme for heating circuit 1. 1) →...
  • Page 27: Changing The Heating Characteristic

    BMK Operating Instructions Changing the heating characteristic BS-07-04-00-00-02-BAEN The heating circuits/charging pumps can only be called into action during the times enabled in the timer programme. The example set out below illustrates programming the heating characteristic for heating circuit 1: 1) →...
  • Page 28: Changing The Hot Water Temperature Setting

    BMK Operating Instructions Changing the required hot water temperature BS-07-05-00-00-01-BAEN You can change the required hot water temperature on the Hot Water menu. The example set out below illustrates programming the required temperature for DHW cylinder 0: 1) → Press the "House level" button 2) →...
  • Page 29: Analogue Room Stat

    BMK Operating Instructions Analogue room stat BS-07-06-00-00-01-BAEN If your system is fitted with an outside-temperature based heating circuit controller, each heating circuit can be equipped with an analogue room stat if desired. The control knob on the room stat allows adjustment of the required room temperature preset on the Heating Circuit menu.
  • Page 30: Operating The Heating System

    Commissioning SY-08-01-00-00-01-BAEN BS-08-01-00-01-01-BAEN Initial commissioning Initial commissioning and basic adjustment of the system may only be carried out by GUNTAMATIC engineers or authorised GUNTAMATIC agents. BS-08-01-00-02-01-BAEN Restarting Before starting up the system again in the autumn/winter, carry out the annual check of the control and safety systems to ensure they are safe and functional.
  • Page 31: Fuel Quality

    BMK Operating Instructions Fuel quality BS-08-03-00-00-01-BAEN To ensure trouble-free heating with the boiler, the fuel must be of the right quality. Logs SY-08-03-00-01-01-BAEN Logs should not be burned until they have been • seasoned for at least 1.5 - 2 years. Ideal log length →...
  • Page 32: Heating-Up Procedure

    BMK Operating Instructions Heating-up procedure SY-08-06-00-00-01-BAEN Carry out the heating-up procedure exactly according to the instructions. 8.5.1 Manual heating up BMK-08-06-01-00-01-BAEN Switch on the power switch • Select the desired heating programme • Open the boiler casing doors and the fuel box door •...
  • Page 33: Heating Operation

    BMK Operating Instructions Heating operation (correct operation with thermal store) SY-08-07-00-00-02-BAEN Modern woodburning boilers are always operated in conjunction with one or more thermal stores. The basic precondition for trouble-free heating is the correct fuel quality and correct operation with the thermal store. Carefully read through the following points and follow the directions precisely.
  • Page 34: Emptying The Ash

    BMK Operating Instructions Afterwards check whether there is still an adequate fire bed present, then re-stoke → otherwise repeat the heating-up procedure. Adjust the refuelling amount to suit the heat demand (check "Th. store/Boiler info" on the display and decide on the amount of fuel to add on that basis).
  • Page 35: Cleaning And Care

    BMK Operating Instructions Cleaning/Care BS-09-00-00-00-01-BAEN SY-09-00-00-01-01-BAEN To obtain the greatest possible efficiency levels and optimum fuel burning characteristics, the boiler including the flue gas passages has to be regularly cleaned. Thanks to the well thought-out boiler design, this can be done very quickly and easily.
  • Page 36: Interim Cleaning

    BMK Operating Instructions Interim cleaning BMK-09-01-00-00-01-BAEN Every 1- 2 weeks Clean the ash out of the fuel box (1) and the grate area (2) • Clean the ash out of the flame duct (17), combustion chamber (6) and • the space above it Check the secondary air duct (18) (vertical air duct) •...
  • Page 37: Rectifying Faults

    BMK Operating Instructions Rectifying faults BMK-10-00-00-00-01-BAEN Fault Cause/Function Remedy Control panel cannot be Power supply disconnected Check external mains plug and/or power • • switched on supply lead between circuit boards Check fuse in supply lead and on the • Fuse blown control panel circuit board •...
  • Page 38: Replacing Fuses

    BMK Operating Instructions Replacing fuses BS-12-00-00-00-01-BAEN Danger: Repair work may only be carried out by authorised technicians. Touching live electrical components can cause fatal injury. Even when the Power switch is "OFF" some components of the system are still live. Therefore, when carrying out repair work it is imperative that the power supply is disconnected by means of the "mains plug"...
  • Page 39 BMK Operating Instructions Notes BS-D-00-00-00-01-BAEN...
  • Page 40 BMK Operating Instructions BS-E-00-00-00-01-BADE GUNTAMATIC Heiztechnik GmbH A – 4722 PEUERBACH Bruck 7 Tel: 0043 (0) 7276 / 2441-0 Fax: 0043 (0)7276 / 3031 E-mail: info@guntamatic.com...