A.1.2 Port Indicators.......................... 16 Rear Status Indicators .......................... 17 Appendix B Parts List......................19 Rack Mount Parts ..........................19 B.1.1 Two- or Four-Post Rack Mount Parts ..................19 Cables..............................20 Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Page 4
Installing a Power Supply......................25 Fan Modules ............................26 E.3.1 Removing a Fan Module......................26 E.3.2 Installing a Fan Module......................26 Appendix F Regulatory Model Numbers .................27 Appendix G Taiwan RoHS Information ................29 Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Step 3 Attach the mounting brackets and install the switch in an equipment rack (Chapter Step 4 Connect the switch to the power source and network devices (Chapter Step 5 Configure the switch (Chapter Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié. Safety Information Refer to the Arista Networks document Safety Information and Translated Safety Warnings available at: https://www.arista.com/en/support/product-documentation Obtaining Technical Assistance Any customer, partner, reseller or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways: Email: support@arista.com.
Note All PSU models are not supported by all switches. Some switches described in this guide could use power supplies that may no longer be available. Contact your local Arista representative for more information. Table 1-4 Switch Specifications (Power Draw)
Clearance areas to the front and rear panels allow for unrestricted cabling. • All front and rear panel indicators can be easily read. • Power cords can reach from the power outlet to the connector on the rear panel. Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Keep replacement parts in their original static-free packaging. • Remove all plastic, foam, vinyl, paper, and other static-generating materials from the work area. • Use tools that do not create ESD. Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
After completing the instructions for your rack type, proceed to Chapter Note Illustrations use a representative Arista switch. Your device may be different in appearance. Two- or Four-Post Rack Mount The switch can be installed in a two- or four-post rack. The installation process is identical because the switch attaches to only two posts of a rack.
Step 2 Select mounting screws that fit your equipment rack. Step 3 Attach the bracket flanges to the rack posts. Figure 3-3: Inserting the Switch into the Rack After completing the rack mount, proceed to Chapter Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Power cords are optional and must be ordered separately. You must use an approved power cord compliant with local and national electrical codes or order one from Arista for use with the device. Important! Installation of this equipment must comply with local and national electrical codes. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.
The power supplies require power cables that comply with IEC-320 and have a C16 plug. Connecting Serial and Management Cables The accessory kit includes the following cables: • RJ-45 to DB-9 serial adapter cable. • RJ-45 Ethernet cable. Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Page 15
USB Port: The USB port may be used for software or configuration updates. • Caution Excessive bending can damage interface cables, especially optical cables. Flexion excessive peut endommager les câbles d’interface, notamment des câbles optiques. Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Page 16
Connecting Serial and Management Cables Chapter 4: Cabling the Switch Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Chapter 5 Configuring the Switch Arista switches ship from the factory in Zero Touch Provisioning (ZTP) mode. ZTP configures the switch without user intervention by downloading a startup configuration file or a boot script from a location specified by a DHCP server. To manually configure a switch, ZTP is bypassed. The initial configuration...
Page 18
When the management port IP address is configured, use this command to access the switch from a host, using the address configured in step 9: ssh admin@192.0.2.8 Refer to the Arista Networks User Manual for complete switch configuration information. Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
The front panel LEDs are labeled as in Figure A-1. Figure A-1: System Status Indicators Note The 2.5G ports are PoE+ (30 W max) and the 5G ports are PoE+ (60 W max) Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
LED states. Port LED behavior for QSFP+ and SFP+ ports is consistent. Table A-2 Port LED States (Front) LED State Status Port link is down. Green Port link is up. Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
The fan has failed. The AC Power Supply Status LEDs are on the power supply modules, as displayed in Figure A-4. Figure A-4: AC Power Supply Status LED Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Page 22
Note You can narrow down the error condition by logging in to the switch to view the specific device state. Refer to the Arista User Manual’s Switch Environment Control chapter, under the topic Viewing show environment Environment Status, for further information on the commands.
Rack Mount Parts B.1.1 Two- or Four-Post Rack Mount Parts Figure B-1: Two- or Four-Post Rack Mount Parts Quantity Description Mounting brackets M4 x 5 Flat head head Phillips Screws Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Description Power cables: IEC-320/C13-C14, 13 A, 250 V RJ-45 Patch Panel Cable RJ-45 to DB9 Adapter Cable Warning All provided power cables are for use only with Arista products. Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
This appendix displays the front panel of all switches covered by this guide. Figure C-1: CCS-720XP-48ZC2 Note The 2.5G ports are PoE+ (30 W max) and the 5G ports are PoE+ (60 W max) Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Page 26
Appendix C: Front Panel Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
All switches covered by this guide use one of the rear panels shown below. Note Depending on the installed power supply and fan modules, the appearance could be different from those shown. Figure D-1: Rear Panel for CCS-720XP-48ZC2 Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
All slots must be filled or covered with a blank for operation (even though power supply or fans may not be functional). • Before you begin, refer to the Arista Networks document Safety Information and Translated Safety Warnings available at: https://www.arista.com/en/support/product-documentation.
Step 2 Slide the new fan module into the switch until the module is fully seated and the release lever snaps into place. Step 3 Verify that the fan module is working normally. Note The fan module status LED should be a steady green for normal operation. Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
This appendix lists the regulatory model numbers (RMNs), where applicable, for the product models for the switches described in this document. Table F-1 Regulatory Model Numbers and Product Numbers Regulatory Model Number (RMN) Product Number(s) AN1712 CCS-720XP-48ZC2 Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Page 32
Appendix F: Regulatory Model Numbers Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Appendix G Taiwan RoHS Information This appendix provides Taiwan RoHS information for switches covered by this guide. For Taiwan BSMI RoHS Table, go to https://www.arista.com/assets/data/pdf/AristaBSMIRoHS.pdf. Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Page 34
Appendix G: Taiwan RoHS Information Quick Start Guide: 720XP Series 1 RU-Gen 3 Cognitive Campus Switches...
Need help?
Do you have a question about the 720XP Series and is the answer not in the manual?
Questions and answers