Hooking Up The Mains Cable - Nice D-Pro Automatic R01 Series Instructions And Warnings For Installation And Use

Industrial
Table of Contents

Advertisement

Available languages

Available languages

Connection
A: MAIN CABLE with CEE connector
B: MOTOR cable
C: FLASHER cable
D: PHOTOCELL cable
E: KEY SWITCH cable
F: Spiral cable for safety edge
Note 1 – If the mains cable is longer than 5 m, you must use a larger diameter.

HOOKING UP THE MAINS CABLE

Three-phase model hookup
L1
L2
L3
N
3
X1
A CEE 16A connector is connected to terminals L1, L2, L3, N and PE.
The D-PRO Automatic can also be hooked up to the mains power supply with
an optional three-phase master power switch. In this case, the CEE connector
may be removed during the installation.
If not already present, the mains cable must be connected to terminals X1 (L1,
L2, L3, N) and PE.
CAUTION: The mains connection must be protected by the manufacturer with
3 x 16A fuses.
Single-phase motor connection
1
5
4
C
Slot on D-PRO X8
CAUTION: The 230/400V jumper at the bottom of the board must be soldered to 230V! D-Pro Automatic control units numbered NDCC1200 to NDCC1299 are
factory set to 230V and supplied with a board pre-installed to X8 for the condenser connection.
TABLE 1 - Technical specifications of electric cables (fig. 2)
Cable type
Motor < 1.5 kW 5 x 0.75 mm
Motor > 1.5 kW 5 x 1.5 mm
Nice provides special cables for their gearmotors as
accessory equipment.
2 x 0.75 mm
4 x 0.5 mm
3 x 2 x 0.25 mm
A Nice spiral cable is available as accessory equipment 4 m
PE
2
A
5
D
PE
L2
L3 N
U
V
W
L1
L2
2
2
(for flasher)
2
2
2
Single-phase model hookup
L1
L2
4
X1
A SCHUKO connector is connected to terminals L1 (N), L2 (phase) and PE.
The D-PRO Automatic can also be hooked up to the mains power supply with
an optional master power switch. In this case, the SCHUKO connector may
be removed during the installation. If using a 200V/DC brake, L2 (N) must be
connected to N on terminal X1.
Functions and parameters
The D-Pro Automatic control unit allows you to select a variety of parameters
during installation and for control. You can activate multiple functions with the
correct value of the corresponding parameter.
The parameters can be modified with the dipswitch settings and the keypad on
the back of the front board; the results are shown on the display.
Further information and a list of parameters are enclosed with these instructions.
Controlling the direction of rotation
IMPORTANT: The door must open 50 cm with the emergency drive to prevent
the lift cable (sectional doors) detaching or the housing winding up (roller and
rapid doors) if the direction of rotation is wrong.
The device can now be activated (insert the CEE connector).
Use the OPEN and CLOSE buttons to check the direction of rotation under the
operator's supervision. If the direction of rotation does not match the direction of
the button's arrow, change the direction of rotation with parameter 75 (P 75 =2).
3
B
U
V
W
Maximum length
1 m (Note 1)
5 - 7 - 11 m
10 m
15 m
10 m
N
PE
A
PE
U
V
W
L1
L2
L3 N
C
D
B
English – 3

Advertisement

Table of Contents
loading

Table of Contents