Nice D-Pro Action Series Instructions And Warnings For Installation And Use

Nice D-Pro Action Series Instructions And Warnings For Installation And Use

Advertisement

Industrial
D-PRO ACTION
Control unit
EN - Instructions and warnings for installation and use
IT - Istruzioni ed avvertenze per l'installazione e l'uso
FR - Instructions et avertissements pour l'installation et l'utilisation
ES - Instrucciones y advertencias para la instalación y el uso
DE - Installierungs-und Gebrauchsanleitungen und Hinweise
PL - Instrukcje i ostrzeżenia do instalacji i użytkowania
NL - Aanwijzingen en aanbevelingen voor installatie en gebruik

Advertisement

Table of Contents
loading

Summary of Contents for Nice D-Pro Action Series

  • Page 1 Industrial D-PRO ACTION Control unit EN - Instructions and warnings for installation and use IT - Istruzioni ed avvertenze per l’installazione e l’uso FR - Instructions et avertissements pour l’installation et l’utilisation ES - Instrucciones y advertencias para la instalación y el uso DE - Installierungs-und Gebrauchsanleitungen und Hinweise PL - Instrukcje i ostrzeżenia do instalacji i użytkowania NL - Aanwijzingen en aanbevelingen voor installatie en gebruik...
  • Page 3: General Warnings: Safety - Installation - Use

    Nice S.p.a. product catalogue. If the product is used in unspecified configurations or with other unspecified products, the requirements may not be guaranteed; the use of the product in such circumstances is prohibited until the installer has verified compliance with the specified requirements of the directive. • “Electromagnetic compatibility” Directive: Special warnings regarding the fitness of use of this product in relation to the “Electromagnetic compatibility” Directive. This product has been subjected to electromagnetic compatibility tests in the most critical situations of use and in the configurations specified in this instruction manual and in combination with the items in the Nice S.p.a. product catalogue. If the product is used in unspecified configurations or with other unspecified products, the electromagnetic compatibility may not be guar- anteed; the use of the product is prohibited in such circumstances until the installer has verified compliance with the specified requirements of the directive. Installation criteria and special warnings in connection with essential requirements • When installed correctly, this product meets the essential requirements laid down in Regulation No. 305/2011 according to the requirements in harmonised standard EN 13241-1, as indicated in Table 1 and in the European directive on “Machinery” 2006/42/EC.
  • Page 4 • As regards the risks of crushing and impact, the doors are protected by means of one of these three methods: 1 - For operation with “hold-to-run command” (man present): as specified in EN 12453, point 5.1.1.4. In this case the command button must be placed in view of the automation and if it is accessible to the public, the command button must not be available to them, e.g. use only with a key switch. 2 - For “Semi-automatic” operation: through the use of an active sensitive edge for limiting the forces as specified in EN 12453, paragraphs 5.1.1.5 and 5.1.3. 3 - For “automatic” operation: through the use of an active sensitive edge for limiting the forces as specified in EN 12453, paragraphs 5.1.1.5 and 5.1.3; in this case, at least one pair of photocells must be installed as shown in Fig. 2. 4 –...
  • Page 5: Table Of Contents

    2.2 - Product application limits The product is only to be used as indicated in the following table: Control unit power Control unit Type of motor supply Three-phase 3x400 V AC – 50/60 NDCC2000 Three-phase 3x400 V AC Hz – with Nice encoder or mechanical NDCC2100 – 50/60 Hz limit switches Single-phase 1x230 V AC – 50/60 Single-phase 1x230 V AC NDCC2200 Hz – with Nice encoder or mechanical – 50/60 Hz limit switches (*) In respect of the corresponding application limits.
  • Page 6: Typical System

    2.3 - Typical system 2.4 - Installation of the control unit Fig. 2 provides an example of an automation system, produced using Proceed as follows when installing the control unit: Nice components: 01. Open the control unit box: unscrew the screws as shown in Fig. 3-A / 1 Gearmotor Fig. 3-B; 2 Transmitter 02. Prepare the holes for routing the electrical cables for the accessories pro- 3 Sensitive edge viding control and/or signalling functions. For this purpose, we recommend...
  • Page 7 Cable type Maximum admissible length A: CONTROL UNIT POWER SUPPLY Cable - NDCC2000, NDCC2100 (three-phase) 4 x 1 mm 5 m (note 1) 2 m (note 1) - NDCC2200 (single-phase) 3 x 0.75 mm B: MOTOR cable special cables for Nice gearmotors are on sale as 5 - 7 - 11 m accessories. for other brands, contact the motor manufacturer C: Cable for FLASHING LIGHT with aerial 2 x 1 mm (for 230 V AC flashing light) 10 m RG58 type shielded cable (aerial) D: PHOTOCELL cable 4 x 0.5 mm...
  • Page 8 SAFETY LED = safety chain LED L2 LED = OK LED (green) LED L1 LED L2 L1 LED = Warning LED (red) slot for the NDA040 accessory board for expanding outputs PROG = DIP switch for programming ENCODER = electronic limit switch external inputs 8 - com (+24 V DC common) INPUT 9 - open LED SAFETY 10 - close 11 - photo (ing1) PROG...
  • Page 9: Electrical Connections

    These outputs can be the mains supply to prevent this risk. The disconnection device is not sup- properly programmed with the Nice Oview programmer. For a description plied with the product. and instructions on programming the available functions, see the NDA040 accessory board manual.
  • Page 10: Electrical Connections Of The Control Unit

    8,2 kΩ brown - 12V DC green - Segnale Signal white - GND/0V 3.4 - Electrical connections of the control unit (Fig. 10) CAUTION! – Before you proceed to make any electrical connections make sure that the mains power supply is disconnected. After attaching the control unit box and preparing the holes for routing the elec- trical cables (see paragraph 2.3), make the electrical connections as follows: If this has not been done yet, first of all connect the power cable:...
  • Page 11: Stop Safety Edge Input

    TABLE 2 SMXI, SMXIS Receiver in “Mode 1 or 2” output description Output No. 1 Step-by-Step Output No. 2 Partial open; factory setting: it opens to halfway (this may be changed during the position acquisition phase or by using the Oview programmer) Output No. 3 Open Output No. 4 Close OXI, OXIT receiver programmed in “extended Mode 2”...
  • Page 12: Recognition Of The Connected Devices And The Opening And Closing Positions

    Set dip switches 1-2- Position Meaning 3-4 to ON = the red Opening Maximum required opening position. When the door and green LEDs start reaches this position it stops. flashing quickly Partial Opening Partial opening position. This is the position at which Press and hold the the door stops after receiving a partial opening com- 3”...
  • Page 13: Recognition Of The Opening And Closing Positions With Mechanical Limit Switch

    Press and hold the STOP button a) Set the limit switch cam 1 E ↑ (green, Fig. 16) to operate the limit 3” for 3 sec. until the red LED flashes switch 2 times b) Tighten the locking screw “A” (Fig. 16) c) For precision adjustment, use screw “B” (Fig. 16). Press the “Close” button to move the door to its maximum closed If you do not want to program the “partial opening” position, set dip position switch 1 to OFF and go directly to step 10 of this procedure...
  • Page 14: Testing And Commissioning

    the movement of the door and check for any defects in assembly or adjust- TABLE 3 ment and for any particular points of friction. DIP1 DIP2 DIP3 DIP4 Function 5 Check, one by one, that all the safety devices featured in the system (photo- Hold-to-run movement cells, sensitive edges, etc.) work properly.
  • Page 15: Diagnostics

    “indicator” terminal on the push button panel housed inside the box cover (Fig. ON. At this point you must repeat the sequence of opening, pause time and 18: terminal 1 -, 2 +). The “indicator” can be installed on the cover itself, by closing. making a hole on the latter, or it can be installed outside the control unit at a CAUTION! - When DIP switch 4 is moved to the OFF position, the pause time maximum distance of 2 m from the latter. is deleted. CAUTION! - The output is not protected against short-circuits.
  • Page 16: Basic Troubleshooting (Resolving Common Problems)

    L1 and L2 LED DIAGNOSTICS Signal Cause Flashes fast alternating red LED and green LED Firmware updating phase in progress 4 flashes - pause - 4 flashes of the LED simultaneously Awaiting firmware updating SAFETY LED DIAGNOSTICS Signal Cause Solution Correct operation Safety chain open The safety chain is made up of the series of inputs (ALT, Stop via button, motor thermal protection, motor release). Close the circuit WHAT TO DO IF…...
  • Page 17: Technical Specifications

    Model NDCC2000 NDCC2100 NDCC2200 Type Control unit for single-phase or three-phase motors with Nice mechanical or electronic limit switches Power supply Three-phase Single-phase 3~400V AC / 3~230V AC (+10% - 10%) 50/60Hz 1~230V AC (+10% - 10%) 50/60Hz Motor max power 2.2kW...
  • Page 18: Ce Declaration Of Conformity

    Declaration in accordance with the following Directives: 2014/30/UE (EMC); 2006/42/EC (MD) Annex II, part B Note: the contents of this declaration corresponds to what is stated in the official document filed in the offices of Nice S.p.a. and, in particular, to the latest version available before printing this manual. The text herein has been re-edited for editorial purposes. A copy of the original declaration can be requested from Nice S.p.A. (TV) I. Declaration number: 536/NDCC2000 Rev.: 1 Language: EN Manufacturer’s Name: NICE S.p.A. Address: Via Pezza Alta 13, 31046 Rustignè di Oderzo (TV) Italy Person authorised to compile the technical documentation: NICE S.p.A. Address: Via Pezza Alta 13, 31046 Rustignè di Oderzo (TV) Italy Type of product: Series D-Pro Action Control units Model/Type: NDCC2000, NDCC2100, NDCC2200 Accessories: Radio receiver models SMXI, SMXIS and ONEXI, Oview, MOFB, MOFOB, F210B, photostrips for TMF sensitive edge, NDA040 The undersigned Roberto Griffa as Chief Executive Officer, hereby declares under his own responsibility that the product identified above complies with the provisions of the following directives: • DIRECTIVE 2014/30/UE OF THE EUROPEAN PARLIAMENT AND COUNCIL of 26 February 2014 on the approximation of the laws of Member States relat- ing to electromagnetic compatibility (rewritten), in accordance with the following harmonised standards: EN 61000-6-2:2005, EN 61000-6-4:2007 + A1:2011 In addition, the product conforms to the following directive in accordance with the provisions applicable to partly completed machinery: • DIRECTIVE 2006/42/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 on machinery, and amending Directive 95/16/EC (rewritten),...

This manual is also suitable for:

Ndcc2100Ndcc2200Ndcc2000

Table of Contents