Load current
Fig. 3-1 Voltage-Current Relation Schema under CC Mode
Under CC mode, the electronic load provides three ways to set constant
current.
Operation steps
1.
2.
3.
4.
5.
6.
7.
8.
I
Load voltage
CC mode
Rotate adjusting knob to set constant current value.
Use numeric keys to input current value and press [Enter] key to
confirm set constant current value.
Use
moving cursor and press
corresponding positions.
Press [CC] key and [Shift] +[CV] to enter parameter setting screen.
Constant
Current
Range=0.000A
Set maximum working current value and press [Enter] for confirmation.
Constant
Current
Range =1.000A
Set maximum voltage value and press [Enter] key.
Constant
Current
High=0.00V
Set minimum voltage value and press [Enter] key.
Constant
Current
Low=0.000V
Set high and low rate and press [Enter] key.
Constant
Current
High-Rate Low-Rate
Set ascending slope and press [Enter] key.
Constant
Current
Rise up=0.000A/uS
Set descending slope and press [Enter] key.
Constant
Current
Rise down=0.000A/uS
Complete parameter setting.
10.0000V
0.0000A
0.00W
CC=1.000A