BEA LZR-FLATSCAN REV-LZ User Manual page 7

Safety sensor for revolving doors
Table of Contents

Advertisement

3
Pass the power cable through the flexible tube.
Connect the plug to the white connector.
5
Take the clamp to fix the flexible tube to the sensor.
Fasten the 2 screws firmly in order to avoid pulling out
the cable.
2
WIRING
12-24 V DC
COM
NC
*
COM
NC
*
* Output status when sensor is operational.
Cut the power cable to the right length, strip the 8 wires and connect all wires as indicated.
The polarity of the power supply is important.
For compliance with EN 16005 and DIN 18650, the door controller test output must be connected and able to test
the sensor.
GREEN
+
BROWN
POWER SUPPLY
-
YELLOW
WHITE
R1
OUTPUT 1
PINK
OUTPUT 2
GREY
R2
RED
TEST
BLUE
4
Make a loop with the wires of the power cable and
pass them through the notch as indicated.
Use the other part of the cable to block the wires.
6
Tighten the other side of the flexible tube using the
cable cap and pass through the rest of the power
cable towards the door controller.
7