Installing The System In The Rack - IBM N3400 Installation And Setup Instructions

Table of Contents

Advertisement

FRONT
Left and Right
Chassis attach screws
Chassis attach screws
Bottom rail screw
Figure 3. N3400 rail mounting template
Note: When installed, each N3400 will occupy a 2U space.
Using one silver pan head M5 screw, attach the rail to the front of the rack using hole H6. Tighten this
screw with a screwdriver.
3. At the rear of the rack, position the rail at the same EIA location used in step 2. Make sure that the
locating pins seat properly in holes H3 and H4. Using two silver pan head M5 screws, attach the rail
to the rack using holes H2 and H5. Tighten these screws with a screwdriver.
4. Tighten the four rail adjustment screws on the installed rail.
5. Repeat steps 2 through 4 for the left-hand rail.

Installing the system in the rack

Use these instructions to install the N3400 in the rack.
18-32 kg (39.7-70.5 lbs)
1. If attached, carefully remove the front bezel of the N3400 by pulling out on the rectangular openings
(marked by blue stripes) on either side of the bezel.
2. From the front of the rack, set the storage system onto the rails and slide it into the rack until the
front mounting bracket of the storage system is a few inches from the rack frame.
As shown in Figure 4 on page 5, position the spacer plates 1 over the locating pins (holes H3 and
H4) on the left and right rails. Slowly slide the chassis into the rack until the front mounting bracket
of the storage system is flush against the spacer plates.
4
Section of rack EIA rail
Rails
H1
H2
H3
H4
H5
H6
CAUTION:
The weight of this part or unit is between 19 and 31 kg (40 and 68 lb). It takes two
persons to safely lift this part or unit.
Top rail screw
Locating pins
Locating pins
Bottom rail screw
REAR
Left and Right
Rails
H1
H2
1 EIA unit (1U)
H3
H4
H5
H6