Qlima SC42 Series Operating Manual page 85

Hide thumbs Also See for SC42 Series:
Table of Contents

Advertisement

Specific information regarding appliances with R290 / R32 refrig-
erant gas.
• Thoroughly read all of the warnings.
• When defrosting and cleaning the appliance, do not use
any tools other than those recommended by the manu-
facturing company.
• The appliance must be placed in an area without any con-
tinuously sources of ignition (for example: open flames,
gas or electrical appliances in operation).
• Do not puncture and do not burn.
• This appliance contains Y g (see rating label back of unit)
of R290 / R32 refrigerant gas.
• R290 / R32 is a refrigerant gas that complies with the
European directives on the environment. Do not puncture
any part of the refrigerant circuit. Be aware the refriger-
ants may not contain an odour.
• If the appliance is installed, operated or stored in a non-
ventilated area, the room must be designed to prevent to
the accumulation of refrigerant leaks resulting in a risk of
fire or explosion due to ignition of the refrigerant caused
by electric heaters, stoves, or other sources of ignition.
• The appliance must be stored in such a way as to prevent
mechanical failure.
• Individuals who operate or work on the refrigerant cir-
cuit must have the appropriate certification issued by
an accredited organization that ensures competence in
handling refrigerants according to a specific evaluation
recognized by associations in the industry.
• Repairs must be performed based on the recommenda-
tion from the manufacturing company.
Maintenance and repairs that require the assistance of other
qualified personnel must be performed under the supervision of
an individual specified in the use of flammable refrigerants.
4
85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents