CAME BX-P Installation Manual
CAME BX-P Installation Manual

CAME BX-P Installation Manual

Automation for sliding gates

Advertisement

Quick Links

AUTOMATION
11 9BT85EN
FOR SLIDING GATES
INSTALLATION MANUAL
BX-P
EN
English

Advertisement

Table of Contents
loading

Summary of Contents for CAME BX-P

  • Page 1 AUTOMATION 11 9BT85EN FOR SLIDING GATES INSTALLATION MANUAL BX-P English...
  • Page 2 • This product should only be used for the purpose for which it was instructions • If the power cable is damaged, it must be replaced by the explicitly designed. Any other use is considered dangerous. CAME Cancelli manufacturer or the technical assistance service or by a person with a Automatici S.p.A.
  • Page 3 4.1 Gearmotor The BX-P ratiomotor is designed and built by CAME CANCELLI AUTOMATICI S.p.A. and it meets the safety standards in force. The case consists partly of cast aluminium, inside of which operates the non-reversible electromechanical gearmotor, and partly of a covering in ABS plastic inside of which is an electronic card, the transformer and the emergency battery holder.
  • Page 4: Description Of Parts

    4.3 Description of parts 1 - Top cover 2 - Settings casing 3 - Control board support 4 - Endstop fins 5 - ZBX8 electronic card 6 - Front cover to control panel 7 - Gearmotor release door 8 - Securing plate 9 - Securing bolt 10 - Securing screw plate 11 - Nut...
  • Page 5: Tools And Materials

    For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and distances. When connecting products that are not specified in this manual, please follow the documentation provided with said products. 5.4 Standard installation 1) BX-P assembly 2) Rack 3) Reception Antenna 4) Flashing light...
  • Page 6 5.5 Securing the plate and installing the assembly The following applications are only examples, as the space for installing the ratiomotor and accessories varies according to obstructions. It is thus up to the system installer to select the most suitable solution. - Dig a pit to the side of the gate (see measurements from diagram).
  • Page 7 - To position the plate in relation to the rack please see the measurements on the diagram. Fill the form box with cement and wait for at least 24 hours for it to solidify. - Remove the form box, fi ll the pit around the cement block with soil. - Unbolt the nuts and washers from the bolts.
  • Page 8 - Remove the cover from the gearmotor by loosening the side bolts, perforate the cable shafts using a screwdriver or a pair of scissors and position the gearmotor atop the plate. Careful! The electric cables must pass through the cable shafts. - Lift the gearmotor from the securing plate by about 5 to 10mm by using the threaded steel-levelling feet to allow any later adjustments between the pinion and the rack.
  • Page 9 - Open and close the gate manually and register the pinion-to-rack distance using the threaded steel-levelling feet (for vertical adjusting) and the slotted holes (horizontal adjusting). This prevents the weight of the gate from bearing on the operator. Rack Rack Pinion Pinion Levelling feet...
  • Page 10: Manually Releasing The Gearmotor

    5.6 Mounting the endstop fins Place the endstop fi ns onto the rack and secure them using a 3 mm Allen wrench. Their positioning limits the gate run. Note: the gate schould not slam against the mechanical stop, when opening or closing. Mechanical stop 5.7 Manually releasing the gearmotor - Insert the trilobed key into the lock, push it in and turn it clockwise ..
  • Page 11: Control Board

    6 Control board 6.1 General description of the ZBX8 card The electronic card is powered by 230V A.C. on terminals L-N, with maximum 50/60Hz frequency. The command accessories run on 24V. Warning! The accessories cannot exceed 40W overall. All of the connections are protected by quick fuses, see table. TAB EL L A FUS IBIL I ZBX8 protecting: fuse:...
  • Page 12: Main Components

    6.2 Main components 1 - Power supply and transformer connection terminal board 2 - 5A line fuse 3 - 1A accessory fuse 4 - Dip-switch "selezione funzioni" 5 - Radiofrequency board coupling for remote control 6 - Trimmer A.C.T.: automatic closing time adjustment 7 - Trimmer PAR.OP.: partial aperture adjustment 8 - Save button of the radio-codes of the remote control 9 - LED signalling the radio-code of the remote control...
  • Page 13 Connections to the systems Stop button (N.C. contact) – Gate leaf stop- button with exclusion of automatic closing phase, resume motion by pressing the push button or remote control. Key selector and/or partial opening button (N.0. contact) - Opens the gate leaf for pedestrian access (adjustable using the trimmer PAR.OP.) Key selector and/or commands button (N.0.
  • Page 14: Electrical Connections

    6.3 Electrical connections Connection for gear motor, limit switch or encoder (Condenser) connecting the standard endstop assembly (see paragraph 6.5) Output for 230V AC motor connection Connections for power source and accessories Eyelet cable terminal with screw and washer for ground connection Possible output of the radio receiver’s second channel (N.O.
  • Page 15: Safety Devices

    Safety devices DIR / DELTAS photocells «partial stop» (N.C.) contact - Input for EN 12978 standard-compliant safety devices such as photocells. Gate stops if moving and automatically shuts (if this functions has been selected). DIR / DELTAS photocells (N.C.) contact for «re-open during closing phase» - Input for EN 12978 standard-compliant safety devices such as photocells.
  • Page 16 6.4 Gearmotor end-stop connection Gearmotor end-stop assembly already connected for For right-hand installation: installation on the left-hand side seen from inside. - reverse FA-FC of the end stops on the terminal board; - reverse the U-V phases of the motor on the terminal board. 6.5 Motor torque limiter To change the torque, move the faston identifi...
  • Page 17: Function Selections

    6.6 Function selections E1 E1 L1T L2T L2T CT VF VF 24 24 12 12 10 10 11 11 TS TS 3P 3P C1 C1 C3 C3 EB EB FA FA ELECTRIC ELECTRIC ACCESSORIES ACCESSORIES BLOCK BLOCK 1A 1A LINE LINE 1.6A 1.6A...
  • Page 18 7 Activating the radio control  Connect the antenna’s RG58 cable. Cut off the main power supply, and remove any batteries.  Fit the AF board onto the electronic board. The electronic board recognizes the AF board only when the operator is powered up again.  Keep the CH1 button on the electronic board pressed: the warning LED flashes.
  • Page 19 8 Installation procedure for automatically releasing the motor (pratico system) The “pratico system” automatically releases the automation through the radio transmitter. In the absence of 230V power, pressing the key (the same one memorized for opening the gate) or with another key of the radio transmitter, the electrical lock is activated, releasing the gearmotor and making it possible to manually open the gate.
  • Page 20: Safety Instructions

    9 Safety instructions Important safety instructions This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous. The manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses. Avoid working close to the hinges or other moving mechanical parts.
  • Page 21: Periodic Maintenance

    10 Maintenance 10.1 Periodic maintenance Periodic maintenance to be carried out by the end-user is as follows: wipe clean the glass surface of the photocells; check that the safety devices work properly; remove any obstructions. We suggest checking the state of lubrication and tightness of the anchoring screws on the operator. -To check the efficiency of the safety devices, move an object in front of the photocells when gate is closing.
  • Page 22: Extraordinary Maintenance

    Periodic maintenance log for end-user (every 6 moths) Signature Date Notes 10.3 Extra-ordinary maintenance The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised firms. N.B.: Any extraordinary maintenance must be performed by specialised technicians. Extra-ordinary maintenance log Installer’s stamp Operator name...
  • Page 23: Phasing Out And Disposal

    CAME CANCELLI AUTOMATICI S.p.A. employs a UNI EN ISO 14001 certified and compliant environmental protection system at its plants, to ensure that environmental safeguarding. We ask you to keep protecting the environment, as CAME deems it to be one of the fundamental points of its market operations strategies, by simply following these brief guidelines when disposing: DISPOSING THE PACKING MATERIALS The packing components (cardboard, plastic, etc.) are solid urban waste and may be disposed of without any particular difficulty, by...
  • Page 24 HR • Za sve dodatne informacije o poduzeću, proizvodima i tehničkoj podršci: UK • Для отримання будь-якої іншої інформації про компанію, продукцію та технічну підтримку: www. came.com www. came.com CAME Cancelli Automatici S.p.a. CAME Cancelli Automatici S.p.a. Via Martiri Della Libertà, 15 31030 Dosson Di Casier...

Table of Contents