Panduit PANZONE PZBASE3 Instructions Manual
Panduit PANZONE PZBASE3 Instructions Manual

Panduit PANZONE PZBASE3 Instructions Manual

Building automation systems

Advertisement

Quick Links

© Panduit Corp. 2007
List of Components:
(1) 36" Edge Grommet
(1) Roll of T
-T
(TTS-20R0)
AK
APE
(1) Installation Instruction
(2) Grounding Cable
(2) Port ID Labels
(6) Screw Caps
(3) PZBR3
(2) #10-24 Acorn Nuts
(2) Washers
(20) Thread Cutting Screws
(3) 3' Sections of Hinged 2" X 2" Panel Duct
Knockout for.50" and.75"
Conduit (4 plcs.)
Knockout for 1.75" and 2"
Conduit (24 plcs.)
Louvered Vents
Reversible Door Hinge Location
Rotating Bracket Accepts up to 3
rack units of patch panels
(shown in the up position)
High Voltage Shield
Space available for a Double Gang
Electrical Box (2 plcs.)
Grounding Studs located on both
the Door and Enclosure Base
Venting for a 4" Fan
FOR TECHNICAL SUPPORT www.panduit.com/resources/install_maintain.asp
P
Z
Building Automation Systems
AN
ONE
Enclosure PZBASE3
INSTRUCTIONS CM336
PZBASE3
(view shown with door removed)
Page 1 of 6
Knockouts for Wireless
Antennas
Knockouts for T70
Raceway
(6 plcs.)

Advertisement

loading

Summary of Contents for Panduit PANZONE PZBASE3

  • Page 1 Building Automation Systems Enclosure PZBASE3 INSTRUCTIONS CM336 © Panduit Corp. 2007 List of Components: (1) 36" Edge Grommet (1) Roll of T (TTS-20R0) (1) Installation Instruction (2) Grounding Cable (2) Port ID Labels (6) Screw Caps (3) PZBR3 (2) #10-24 Acorn Nuts...
  • Page 2 Mount the electrical box. Run con- 32" duit along the outside of enclosure and connect to electrical box through the knockout hole (See figure 1.6b). Option 1 Option 2 Knockout Knockout 1.6b 1.6a For Technical Support: www.panduit.com/resources/install_maintain.asp Page 2 of 6...
  • Page 3 Building Automaton Systems Enclosure 3.2 Attach grounding bracket as shown in figure 3.2. 3.3 Attach main building ground to bracket. 3.4 Attach two solid grounding cables to ground bracket as shown in figure 3.2 For Technical Support: www.panduit.com/resources/install_maintain.asp Page 3 of 6...
  • Page 4 4.2 With Patch Panel Bracket in up the position, install patch pan- els (suggested PANDUIT Part No. CPPL24WBL sold sepa- rately) along with PRBR3 bend radius posts to the front side of the bracket. (See figure 4.2) 4.3 Rotate Patch Panel Bracket down by twisting latches to release...
  • Page 5 5.3 Determine physical space required on perforated panel for each system.(i.e physically lay out control systems on perforated panel). 5.4 Use panel duct (H2x2LG3) to segregate individual control systems. Cut duct to size and secure to perforated panel.. 5.5 Secure all controls to perforated panel. For Technical Support: www.panduit.com/resources/install_maintain.asp Page 5 of 6...
  • Page 6 6.5 Attach the power cord. The fan can be plugged into an Uninterruptable Power Supply (UPS) or the electrical box inside the enclosure. For instuctions in Local Languages E-mail: and Technical Support: cs@panduit.com Fax: www.panduit.com/resources/install_maintain.asp (708)444-6448 www.panduit.com Page 6 of 6...