Operation Process / Photoes
Disassemble Motor
Use a screwdriver to unscrew the two screws fixing the motor
clamp and then remove the motor clamp. Unscrew the 3 holding
screws on the bearing cover and remove the motor.
(refer to Figure 7-11,7-12)
Disassemble Cross Flow Fan
T
ake out the bearing holder at the left, and remove the
cross flow fan.
(refer to Figure 7-13)
clamp
screws
screws
motor
Cross Flow Fan
Bearing Holder
Cross Flow Fan
Fengyun Series
Figure 7-11
Figure 7-12
screw
Figure 7-13