Gree Fengyun Series Manual page 41

Table of Contents

Advertisement

Operating Procedures / Photos
Disassemble Front Case
Unscrew the three screw cover at the front case,
unscrew the six screws, and pull backward the
front case to remove it.
(refer to Figure 7-4)
Disassemble Electric Box Cover
Unscrew the screw fixing the light plate to
remove the light plate. Hold the electric box
cover to press it inward so that the clasps at both
sides are loose. Lift the electric box cover to
remove it.
(refer to Figure 7-5)
Disassemble Electric Box
Remove the grounding wire of evaporator. Take
apart the tube sensor. Unplug the socket
connecters of indoor motor and swing motor at
the electric box. Use screwdriver to screw off the
fixing screw of electric box. Take out the electric
box.
(refer to Figure 7-6)
Screw
Screw
Lamp board
Tube Sensor
Grounding Wire
Room Sensor
Fengyun Series
Figure 7-4
Clasp
Electric
Box Cover
Figure 7-5
Figure 7-6