Water Leakage - Gree Fengyun Series Manual

Table of Contents

Advertisement

Abnormal sound
and vibration

Water leakage

Fan of indoor unit touches other
positions
Foreign articles inside the indoor unit
Vibration of compressor is violent
Pipes of outdoor unit bump together
Metal plates bump together inside the
unit
Indoor fan bumps cabinet
Abnormal sound from inside compressor
Abnormal electromagnetic noise from
4-way valve when in heating operation
Block or breakage of drainage pipe
The refrigerant pipe joint is not
wrapped firmly
Adjust fan position
Remove foreign articles
Adjust
support
foot
compressor, tighten loose bolts
Separate bumping pipes
1. Tighten connection screws
2. Attach vibration damping gum
between metal plates
Adjust fan position
Replace Compressor
Internal short circuit of solenoid
valve, replace solenoid valve
Replace drainage pipe
Wrap and bind it again firmly
mat
of

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents